Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 196

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Electrophysiological and Electrocardiographic Characteristics of Focal Atrial Tachycardia Originating From the Pulmonary Veins: Acute and Long-Term Outcomes of Radiofrequency Ablation

Kistler, Peter M., Sanders, Prashanthan, Fynn, Simon P., Stevenson, Irene H., Hussin, Azlan, Vohra, Jitendra K., Sparks, Paul B., Kalman, Jonathan M. · 2003 · Circulation

Abstract

Background— The objective of this study was to describe the electrophysiological characteristics, anatomic distribution, and long-term outcome after focal ablation (RFA) of pulmonary vein (PV) atrial tachycardia (AT). Both atrial fibrillation (AF) and AT may be due to a rapidly firing focus in the PVs. Whether these represent two aspects of the same process is unknown. Methods and Results— Twenty-seven patients with 28 PV(16%) ATs of a consecutive series of 172 undergoing RFA for focal AT are reported. The mean age was 39±16 years, with symptoms for 9±14 years resistant to 1.7±0.8 medications. AT occurred spontaneously or with isoproterenol in all patients and was not inducible with PES in any. The distribution of PV ATs was right superior PV, 11; left superior PV, 11; left inferior PV, 5; and right inferior PV, 1; 26of 28 foci (93%) were ostial. RFA was successful in 28 of 28 PV ATs acutely. RFA was focal in 25 of 28, with PV isolation of a single target vein in 3. There were 4 recurrences at a mean of 3.3 months. Repeat RFA was performed in all 4 and successful in 3 of 4. All but one recurrence occurred from the same site. Long-term success was achieved in 26 of 27 (96%) patients at mean follow-up of 25±22 months. No patients have had subsequent development of AF or AT from a different site. Conclusions— PV AT has a distribution similar to PV AF, with a propensity to upper veins. However, the majority of foci are ostial, and only a small percentage occur from deep in the PV. Focal RFA is associated with high long-term success, with freedom from both AT from other sites and from AF. PV AT is a localized process and therefore may be different from PV AF.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.0000095269.36984.75

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 196

Metadata

Authors
Kistler, P. M., Sanders, P., Fynn, S. P., Stevenson, I. H., Hussin, A., Vohra, J. K., Sparks, P. B., & Kalman, J. M.
Venue
Circulation
Published
2003-10-21
Volume
108
Issue
16
Pages
1968-1975
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2064809967
Cited by
196
References
3
FWCI
7.75
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Electrophysiological and Electrocardiographic Characteristics of Focal Atrial Tachycardia Originating From the Pulmonary Veins: Acute and Long-Term Outcomes of Radiofrequency Ablation. https://app.cochat.ai/papers/10.1161/01.cir.0000095269.36984.75
The paper
Kistler, P. M., Sanders, P., Fynn, S. P., Stevenson, I. H., Hussin, A., Vohra, J. K., Sparks, P. B., & Kalman, J. M. (2003). Electrophysiological and Electrocardiographic Characteristics of Focal Atrial Tachycardia Originating From the Pulmonary Veins: Acute and Long-Term Outcomes of Radiofrequency Ablation. Circulation. https://doi.org/10.1161/01.cir.0000095269.36984.75

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.