Analysis of 1-Year Clinical Outcomes in the SIRIUS Trial: A Randomized Trial of a Sirolimus-Eluting Stent Versus a Standard Stent in Patients at High Risk for Coronary Restenosis
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
Background— This study evaluated a large group of patients enrolled in a double-blind randomized trial of the sirolimus-eluting stent to document whether the initial clinical improvement seen in previous smaller series is maintained out to 12 months and to study the potential treatment effect in patient subsets known to be at increased risk of restenosis. Methods and Results— A total of 1058 patients with de novo native coronary stenosis undergoing clinically indicated percutaneous coronary intervention were randomly assigned to sirolimus-eluting stent (533) or control bare stent (525). Procedural success and in-hospital outcomes were excellent and did not differ between the 2 groups. At 9 months, clinical restenosis, defined as target-lesion revascularization, was 4.1% in the sirolimus limb versus 16.6% in the control limb ( P <0.001). At 12 months, the absolute difference in target-lesion revascularization continued to increase and was 4.9% versus 20% ( P <0.001). There were no differences in death or myocardial infarction rates. In high-risk patient subsets, defined by vessel size, lesion length, and presence of diabetes mellitus, there was a 70% to 80% reduction in clinical restenosis at 1 year. Conclusions— Placement of the sirolimus-eluting stent results in continued clinical improvement at 1 year after initial implantation, with significant reduction in clinical restenosis as defined by target-lesion revascularization. Between 9 and 12 months, the absolute reduction of clinical restenosis continues to increase. Even in high-risk subsets of patients, there is a 70% to 80% relative reduction in clinical restenosis at 12 months with this drug-eluting stent.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Serruys, P. W., de Jaegere, P., Kiemeneij, F., Macaya, C., Rutsch, W., Heyndrickx, G., Emanuelsson, H., Marco, J., Legrand, V., Materne, P., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310801 · Cited by 4,556
Fischman, D. L., Leon, M. B., Baim, D. S., Schatz, R. A., Savage, M. P., Penn, I., Detre, K., Veltri, L., Ricci, D., Nobuyoshi, M., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310802 · Cited by 4,271
Self-citationMoses, J. W., Leon, M. B., Popma, J. J., Fitzgerald, P. J., Holmes, D. R., O'Shaughnessy, C., Caputo, R. P., Kereiakes, D. J., Williams, D. O., Teirstein, P. S., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa035071 · Cited by 4,224
Self-citationMorice, M.-C., Serruys, P. W., Sousa, J. E., Fajadet, J., Ban Hayashi, E., Perin, M., Colombo, A., Schuler, G., Barragan, P., Guagliumi, G., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa012843 · Cited by 4,033
Colombo, A., Drzewiecki, J., Banning, A., Grube, E., Hauptmann, K., Silber, S., Dudek, D., Fort, S., Schiele, F., Zmudka, K., et al. (2003) · Circulation · doi:10.1161/01.cir.0000086926.62288.a6 · Cited by 1,016
van der Giessen, W. J., Lincoff, A. M., Schwartz, R. S., van Beusekom, H. M. M., Serruys, P. W., Holmes, D. R., Ellis, S. G., & Topol, E. J. (1996) · Circulation · doi:10.1161/01.cir.94.7.1690 · Cited by 852
Self-citationSousa, J. E., Costa, M. A., Abizaid, A., Abizaid, A. S., Feres, F., Pinto, I. M. F., Seixas, A. C., Staico, R., Mattos, L. A., Sousa, A. G. M. R., et al. (2001) · Circulation · doi:10.1161/01.cir.103.2.192 · Cited by 793
Self-citationTopol, E. J., Leya, F., Pinkerton, C. A., Whitlow, P. L., Hofling, B., Simonton, C. A., Masden, R. R., Serruys, P. W., Leon, M. B., Williams, D. O., et al. (1993) · New England Journal of Medicine · doi:10.1056/nejm199307223290401 · Cited by 698
Self-citationClinical restenosis after coronary stenting: perspectives from multicenter clinical trials
Cutlip, D. E., Chauhan, M. S., Baim, D. S., Ho, K. K. L., Popma, J. J., Carrozza, J. P., Cohen, D. J., & Kuntz, R. E. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02597-4 · Cited by 423
Self-citationResults of Prevention of REStenosis with Tranilast and its Outcomes (PRESTO) Trial
Holmes, D. R., Savage, M., LaBlanche, J.-M., Grip, L., Serruys, P. W., Fitzgerald, P., Fischman, D., Goldberg, S., Brinker, J. A., Zeiher, A. M., et al. (2002) · Circulation · doi:10.1161/01.cir.0000028335.31300.da · Cited by 260
Self-citationEvidence for Use of Coronary Stents: A Hierarchical Bayesian Meta-Analysis
Brophy, J. M., Belisle, P., & Joseph, L. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-10-200305200-00005 · Cited by 207
Liistro, F., Stankovic, G., Di Mario, C., Takagi, T., Chieffo, A., Moshiri, S., Montorfano, M., Carlino, M., Briguori, C., Pagnotta, P., et al. (2002) · Circulation · doi:10.1161/01.cir.0000016042.69606.61 · Cited by 192
Rensing, B. (2001) · European Heart Journal · doi:10.1053/euhj.2001.2892 · Cited by 183
Baim, D. S., Cutlip, D. E., O’Shaughnessy, C. D., Hermiller, J. B., Kereiakes, D. J., Giambartolomei, A., Katz, S., Lansky, A. J., Fitzpatrick, M., Popma, J. J., et al. (2001) · The American Journal of Cardiology · doi:10.1016/s0002-9149(00)01307-2 · Cited by 113
Self-citationBaim, D. S., Cutlip, D. E., Midei, M. G., Linnemeier, T. J., SCHREIBER, T. L., Cox, D. A., Kereiakes, D. J., Popma, J. J., Robertson, L. K., Prince, R., et al. (2001) · The American Journal of Cardiology · doi:10.1016/s0002-9149(00)01308-4 · Cited by 78
Self-citationUsefulness of stent length in predicting in-stent restenosis (the MULTI-LINK stent trials)
Kereiakes, D. J., Linnemeier, T. J., Baim, D. S., Kuntz, R. E., O’Shaughnessy, C. D., Hermiller, J. B., Fink, S., Lansky, A. J., Nishimura, N., Broderick, T. M., et al. (2000) · The American Journal of Cardiology · doi:10.1016/s0002-9149(00)00928-0 · Cited by 75
Self-citationData and Safety Monitoring Boards
Friedman, L. M. (2002) · Elsevier eBooks · doi:10.1016/b978-012274065-7/50008-3 · Cited by 48
ALLEN, G. W. (1883) · New England Journal of Medicine · doi:10.1056/nejm188308091090606 · Cited by 36
Cited by
WRITING COMMITTEE MEMBERS, Smith, S. C., Feldman, T. E., Hirshfeld, J. W., Jacobs, A. K., Kern, M. J., King, S. B., Morrison, D. A., O’Neill, W. W., Schaff, H. V., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.170815 · Cited by 2,218
Stent Thrombosis in Randomized Clinical Trials of Drug-Eluting Stents
Mauri, L., Hsieh, W.-H., Massaro, J. M., Ho, K. K. L., D'Agostino, R., & Cutlip, D. E. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa067731 · Cited by 1,441
Self-citationKing, S. B., Smith, S. C., Hirshfeld, J. W., Jacobs, A. K., Morrison, D. A., Williams, D. O., 2005 WRITING COMMITTEE MEMBERS, Smith, S. C., Feldman, T. E., Hirshfeld, J. W., et al. (2008) · Circulation · doi:10.1161/circulationaha.107.188208 · Cited by 1,014
2007 Focused Update of the ACC/AHA/SCAI 2005 Guideline Update for Percutaneous Coronary Intervention
King, S. B., Smith, S. C., Hirshfeld, J. W., Morrison, D. A., Williams, D. O., & Jacobs, A. K. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.10.002 · Cited by 612
Finn, A. V., Kolodgie, F. D., Harnek, J., Guerrero, L. J., Acampado, E., Tefera, K., Skorija, K., Weber, D. K., Gold, H. K., & Virmani, R. (2005) · Circulation · doi:10.1161/circulationaha.104.508937 · Cited by 556
Metadata
- Authors
- Holmes, D. R., Leon, M. B., Moses, J. W., Popma, J. J., Cutlip, D., Fitzgerald, P. J., Brown, C., Fischell, T., Wong, S. C., Midei, M., Snead, D., & Kuntz, R. E.
- Venue
- Circulation
- Published
- 2004-02-10
- Volume
- 109
- Issue
- 5
- Pages
- 634-640
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2124242147
- Cited by
- 515
- References
- 18
- FWCI
- 72.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.