The DOI matches its Crossref record.
Resumption of Electrical Conduction in Previously Isolated Pulmonary Veins: Rationale for a Different Strategy?
Open accessAbstract
Background— Atrial fibrillation (AF) may recur after pulmonary vein isolation (PVI) as the result of either recurrent PV conduction or non-PV foci. This study characterized the electrophysiological findings of patients with recurrent AF after initially successful PVI and the clinical outcome after a repeat procedure. Methods and Results— Among 185 patients undergoing PVI, 52 reported no significant improvement in their clinical course. We analyzed PV conduction in 51 PVs (15 patients) at repeat PVI. All PVs were isolated with either RF (30 W, 50°C, 60 seconds) or cryoablation (−80°C for 5 minutes). At repeat study, 42 of the previously isolated 51 PVs had return of conduction. All patients had recurrent conduction in ≥2 PVs, with only 1 non-PV focus identified. The mean number of RF applications required to re-isolate the PVs was fewer at the repeat compared with the initial procedure (10±6 versus 4±2, P <0.005). Over a period of 15±6 months, all but 1 patient was clinically improved by the second procedure. Conclusions— In patients with recurrent AF after PVI, return of PV conduction can be expected. Repeat PVI provides significant clinical benefit for these patients. These results suggest that if permanent PV isolation is the ablation strategy, different techniques may be required to improve long-term efficacy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hindricks, G., Potpara, T., Dagres, N., Arbelo, E., Bax, J. J., Blomström-Lundqvist, C., Boriani, G., Castella, M., Dan, G.-A., Dilaveris, P. E., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehaa612 · Cited by 9,971
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Calkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.04.005 · Cited by 1,701
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-012-9672-7 · Cited by 1,675
Metadata
- Authors
- Nanthakumar, K., Plumb, V. J., Epstein, A. E., Veenhuyzen, G. D., Link, D., & Kay, G. N.
- Venue
- Circulation
- Published
- 2004-03-16
- Volume
- 109
- Issue
- 10
- Pages
- 1226-1229
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1966065754
- Cited by
- 236
- References
- 0
- FWCI
- 9.50
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Resumption of Electrical Conduction in Previously Isolated Pulmonary Veins: Rationale for a Different Strategy? https://app.cochat.ai/papers/10.1161/01.cir.0000121423.78120.49
- The paper
- Nanthakumar, K., Plumb, V. J., Epstein, A. E., Veenhuyzen, G. D., Link, D., & Kay, G. N. (2004). Resumption of Electrical Conduction in Previously Isolated Pulmonary Veins: Rationale for a Different Strategy? Circulation. https://doi.org/10.1161/01.cir.0000121423.78120.49
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.