Value of Programmed Ventricular Stimulation After Tetralogy of Fallot Repair: A Multicenter Study

Khairy, Paul, Landzberg, Michael J., Gatzoulis, Michael A., Lucron, Hugues, Lambert, Jean, Marçon, François, Alexander, Mark E., Walsh, Edward P.·2004·Circulation

Abstract

Background— Studies have consistently shown that ventricular tachycardia (VT) and sudden cardiac death (SCD) complicate the long-term outcome after tetralogy of Fallot repair, yet the diagnostic and predictive value of electrophysiological testing in this population is uncertain. Methods and Results— A multicenter cohort of 252 patients with repaired tetralogy of Fallot undergoing programmed ventricular stimulation was followed up for 18.5±9.6 and 6.5±4.5 years after corrective surgery and electrophysiological testing, respectively. Clinical VT and/or SCD occurred in 24.6%. Sustained monomorphic VT and polymorphic VT were induced in 30.2% and 4.4%. Including polymorphic VT in the definition of inducibility improved sensitivity (66.1±6.0% versus 77.4±5.3%, P =0.0082) with a marginal reduction in specificity (81.6±2.8% versus 79.5±2.9%, P =0.0455). Positive and negative predictive values were 55.2±5.3% and 91.5±2.2%. Independent risk factors for inducibility were age at study ≥18 years (OR, 3.3), palpitations (OR, 2.8), prior palliative surgery (OR, 3.1), modified Lown criteria ≥2 (OR, 5.6), and cardiothoracic ratio ≥0.6 (OR, 3.3). Event-free survival rates in noninducible and inducible patients at 1, 5, 10, and 15 years were 97.9%, 92.8%, 89.3%, and 89.3% versus 79.4%, 62.6%, 58.7%, and 50.3%, respectively ( P <0.0001). Both inducible monomorphic VT [relative risk (RR), 5.0; P =0.0002] and polymorphic VT (RR, 12.9; P <0.0001) predicted future clinical VT and SCD. In a multivariate analysis, inducible sustained VT was an independent risk factor for subsequent events (RR, 4.7; 95% CI, 1.2 to 18.5; P =0.0268). Conclusions— Programmed ventricular stimulation is of diagnostic and prognostic value in risk stratifying patients with repaired tetralogy of Fallot. In this patient population, inducible sustained polymorphic VT should not be disregarded as nonspecific.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.0000126495.11040.bd

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 436

Metadata

Authors
Khairy, P., Landzberg, M. J., Gatzoulis, M. A., Lucron, H., Lambert, J., Marçon, F., Alexander, M. E., & Walsh, E. P.
Venue
Circulation
Published
2004-04-27
Volume
109
Issue
16
Pages
1994-2000
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2084235265
Cited by
436
References
5
FWCI
9.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Value of Programmed Ventricular Stimulation After Tetralogy of Fallot Repair: A Multicenter Study. https://app.cochat.ai/papers/10.1161/01.cir.0000126495.11040.bd
The paper
Khairy, P., Landzberg, M. J., Gatzoulis, M. A., Lucron, H., Lambert, J., Marçon, F., Alexander, M. E., & Walsh, E. P. (2004). Value of Programmed Ventricular Stimulation After Tetralogy of Fallot Repair: A Multicenter Study. Circulation. https://doi.org/10.1161/01.cir.0000126495.11040.bd

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.