Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 350

The DOI matches its Crossref record.

Stent Thrombosis After Successful Sirolimus-Eluting Stent Implantation

Jeremias, Allen, Sylvia, Brett, Bridges, Jonathan, Kirtane, Ajay J., Bigelow, Brian, Pinto, Duane S., Ho, Kalon K.L., Cohen, David J., Garcia, Lawrence A., Cutlip, Donald E., Carrozza, Joseph P.·2004·Circulation

Abstract

Background— Stent thrombosis (ST) is a rare but devastating complication of coronary stent implantation, occurring in 0.5% to 1.9% of patients with bare metal stents. The incidence of ST with drug-eluting stents is less well studied, particularly among patients outside of clinical trials. Methods and Results— The aim of this study was to evaluate the incidence and potential risk factors for ST in patients receiving sirolimus-eluting stents (SES) in the “real world” after commercial release in the United States in April 2003. All 652 patients who underwent SES implantation (776 lesions treated) at our institution between April and October 2003 were followed up prospectively after the procedure (median follow-up 100 days). During that period, 7 patients (1.1%, 95% CI 0.4% to 2.2%) developed ST within a range of 2 to 13 days, and 1 patient had an ST-elevation myocardial infarction on day 39 with evidence of thrombus within the SES at angiography. Patients with an ST had significantly smaller final nominal balloon diameters (2.75 versus 3.00 mm, P =0.04), and in 4 (57%) of the 7 patients with ST versus 1.7% of patients without ST ( P <0.001), antiplatelet therapy had been discontinued after the procedure. Among the ST patients, 1 died and 5 had myocardial infarctions. Conclusions— In this single-center experience, the incidence of ST after SES implantation was ≈1%, which is within the expected range of bare metal stents. The discontinuation of antiplatelet therapy was strongly associated with the development of ST in this patient population.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.0000127105.99982.21

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 350

Metadata

Authors
Jeremias, A., Sylvia, B., Bridges, J., Kirtane, A. J., Bigelow, B., Pinto, D. S., Ho, K. K. L., Cohen, D. J., Garcia, L. A., Cutlip, D. E., & Carrozza, J. P.
Venue
Circulation
Published
2004-04-27
Volume
109
Issue
16
Pages
1930-1932
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2112145710
Cited by
350
References
0
FWCI
45.44
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Stent Thrombosis After Successful Sirolimus-Eluting Stent Implantation. https://app.cochat.ai/papers/10.1161/01.cir.0000127105.99982.21
The paper
Jeremias, A., Sylvia, B., Bridges, J., Kirtane, A. J., Bigelow, B., Pinto, D. S., Ho, K. K. L., Cohen, D. J., Garcia, L. A., Cutlip, D. E., & Carrozza, J. P. (2004). Stent Thrombosis After Successful Sirolimus-Eluting Stent Implantation. Circulation. https://doi.org/10.1161/01.cir.0000127105.99982.21

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.