Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 200

The DOI matches its Crossref record.

Non–Polymer-Based Paclitaxel-Coated Coronary Stents for the Treatment of Patients With De Novo Coronary Lesions: Angiographic Follow-Up of the DELIVER Clinical Trial

Open access
Lansky, Alexandra J., Costa, Ricardo A., Mintz, Gary S., Tsuchiya, Yoshihiro, Midei, Mark, Cox, David A., O’Shaughnessy, Charles, Applegate, Robert A., Cannon, Louis A., Mooney, Michael, Farah, Anthony, Tannenbaum, Mark A., Yakubov, Steven, Kereiakes, Dean J., Wong, S. Chiu, Kaplan, Barry, Cristea, Ecaterina, Stone, Gregg W., Leon, Martin B., Knopf, William D., O’Neill, William W.·2004·Circulation

Abstract

Background— Paclitaxel, a microtubule-stabilizing compound with potent antitumor activity, has been shown to inhibit smooth muscle cell proliferation and migration. The DELIVER trial was a prospective, randomized, blinded, multicenter clinical evaluation of the non–polymer-based paclitaxel-coated ACHIEVE stent compared with the stainless steel Multi-Link (ML) PENTA stent. Methods and Results— A total of 1043 patients with focal de novo coronary lesions, <25 mm in length, in 2.5- to 4.0-mm vessels were randomized (ACHIEVE n=524; ML PENTA n=519). Angiographic follow-up was performed in a subset of 442 patients (ACHIEVE n=228; ML PENTA n=214). Prespecified end points were a 40% reduction in target-vessel failure at 9 months (primary clinical end point) and a 50% reduction in binary restenosis at 8 months (major secondary end point). Baseline clinical characteristics were comparable between the groups. Patients in ACHIEVE had more type C lesions and a larger reference diameter. At follow-up, stent late loss was 0.81 versus 0.98 mm ( P =0.003), stent binary restenosis was 14.9% versus 20.6% ( P =0.076), and target-vessel failure was 11.9% versus 14.5% ( P =0.12) for ACHIEVE and ML PENTA, respectively. Conclusions— The ACHIEVE paclitaxel-coated stent decreased neointimal proliferation compared with the bare-metal PENTA stent; however, this reduction was insufficient to meet the prespecified primary end point of target-vessel failure and the secondary end point of binary restenosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.0000127129.94129.6f

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 200

Metadata

Authors
Lansky, A. J., Costa, R. A., Mintz, G. S., Tsuchiya, Y., Midei, M., Cox, D. A., O’Shaughnessy, C., Applegate, R. A., Cannon, L. A., Mooney, M., Farah, A., Tannenbaum, M. A., Yakubov, S., Kereiakes, D. J., Wong, S. C., Kaplan, B., Cristea, E., Stone, G. W., Leon, M. B., Knopf, W. D., & O’Neill, W. W.
Venue
Circulation
Published
2004-04-27
Volume
109
Issue
16
Pages
1948-1954
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2148865658
Cited by
200
References
0
FWCI
31.20
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Non–Polymer-Based Paclitaxel-Coated Coronary Stents for the Treatment of Patients With De Novo Coronary Lesions: Angiographic Follow-Up of the DELIVER Clinical Trial. https://app.cochat.ai/papers/10.1161/01.cir.0000127129.94129.6f
The paper
Lansky, A. J., Costa, R. A., Mintz, G. S., Tsuchiya, Y., Midei, M., Cox, D. A., O’Shaughnessy, C., Applegate, R. A., Cannon, L. A., Mooney, M., Farah, A., Tannenbaum, M. A., Yakubov, S., Kereiakes, D. J., Wong, S. C., Kaplan, B., Cristea, E., Stone, G. W., Leon, M. B., . . . O’Neill, W. W. (2004). Non–Polymer-Based Paclitaxel-Coated Coronary Stents for the Treatment of Patients With De Novo Coronary Lesions: Angiographic Follow-Up of the DELIVER Clinical Trial. Circulation. https://doi.org/10.1161/01.cir.0000127129.94129.6f

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.