The DOI matches its Crossref record.
Spiral Computed Tomography for Acute Pulmonary Embolism
Abstract
There is still considerable debate about the optimal diagnostic imaging modality for acute pulmonary embolism. If imaging is deemed necessary from an initial clinical evaluation such as d -dimer testing, options include nuclear medicine scanning, catheter pulmonary angiography, and spiral CT. In many institutions, spiral CT is becoming established as the first-line imaging test in daily clinical practice. With spiral CT, thrombus is directly visualized, and both mediastinal and parenchymal structures are evaluated, which may provide important alternative or additional diagnoses. However, limitations for the accurate diagnosis of small peripheral emboli, with a reported miss rate of up to 30% with single-slice spiral CT so far, have prevented the unanimous embrace of spiral CT as the new standard of reference for imaging pulmonary embolism. The clinical significance of the detection and treatment of isolated peripheral pulmonary emboli is uncertain. Evidence is accumulating that it is safe practice to withhold anticoagulation in patients with suspected pulmonary embolism on the basis of a negative spiral CT study. Remaining concerns about the accuracy of spiral CT for pulmonary embolism detection may be overcome by the introduction of multidetector-row spiral CT. This widely available technology has improved visualization of peripheral pulmonary arteries and detection of small emboli. The most recent generation of multidetector-row spiral CT scanners appears to outperform competing imaging modalities for the accurate detection of central and peripheral pulmonary embolism. In this review, we assess the current role and future potential of CT in the diagnostic algorithm of acute pulmonary embolism.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kucher, N., Rossi, E., De Rosa, M., & Goldhaber, S. Z. (2006) · Circulation · doi:10.1161/circulationaha.105.592592 · Cited by 780
Self-citationMultidetector-Row Computed Tomography in Suspected Pulmonary Embolism
Perrier, A., Roy, P.-M., Sanchez, O., Le Gal, G., Meyer, G., Gourdier, A.-L., Furber, A., Revel, M.-P., Howarth, N., Davido, A., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa042905 · Cited by 642
Anderson, D. R., Kahn, S. R., Rodger, M. A., Kovacs, M. J., Morris, T., Hirsch, A., Lang, E., Stiell, I., Kovacs, G., Dreyer, J., et al. (2007) · JAMA · doi:10.1001/jama.298.23.2743 · Cited by 566
Schoepf, U. J., Kucher, N., Kipfmueller, F., Quiroz, R., Costello, P., & Goldhaber, S. Z. (2004) · Circulation · doi:10.1161/01.cir.0000147612.59751.4c · Cited by 489
Self-citation
Metadata
- Authors
- Schoepf, U. J., Goldhaber, S. Z., & Costello, P.
- Venue
- Circulation
- Published
- 2004-05-11
- Volume
- 109
- Issue
- 18
- Pages
- 2160-2167
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2171447203
- Cited by
- 237
- References
- 0
- FWCI
- 20.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Spiral Computed Tomography for Acute Pulmonary Embolism. https://app.cochat.ai/papers/10.1161/01.cir.0000128813.04325.08
- The paper
- Schoepf, U. J., Goldhaber, S. Z., & Costello, P. (2004). Spiral Computed Tomography for Acute Pulmonary Embolism. Circulation. https://doi.org/10.1161/01.cir.0000128813.04325.08
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.