Modern Pacemaker and Implantable Cardioverter/Defibrillator Systems Can Be Magnetic Resonance Imaging Safe: In Vitro and In Vivo Assessment of Safety and Function at 1.5 T
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Background— MRI has unparalleled soft-tissue imaging capabilities. The presence of devices such as pacemakers and implantable cardioverter/defibrillators (ICDs), however, is historically considered a contraindication to MRI. These devices are now smaller, with less magnetic material and improved electromagnetic interference protection. Our aim was to determine whether these modern systems can be used in an MR environment. Methods and Results— We tested in vitro and in vivo lead heating, device function, force acting on the device, and image distortion at 1.5 T. Clinical MR protocols and in vivo measurements yielded temperature changes <0.5°C. Older (manufactured before 2000) ICDs were damaged by the MR scans. Newer ICD systems and most pacemakers, however, were not. The maximal force acting on newer devices was <100 g. Modern (manufactured after 2000) ICD systems were implanted in dogs (n=18), and after 4 weeks, 3- to 4-hour MR scans were performed (n=15). No device dysfunction occurred. The images were of high quality with distortion dependent on the scan sequence and plane. Pacing threshold and intracardiac electrogram amplitude were unchanged over the 8 weeks, except in 1 animal that, after MRI, had a transient (<12 hours) capture failure. Pathological data of the scanned animals revealed very limited necrosis or fibrosis at the tip of the lead area, which was not different from controls (n=3) not subjected to MRI. Conclusions— These data suggest that certain modern pacemaker and ICD systems may indeed be MRI safe. This may have major clinical implications for current imaging practices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kim, R. J., Wu, E., Rafael, A., Chen, E.-L., Parker, M. A., Simonetti, O., Klocke, F. J., Bonow, R. O., & Judd, R. M. (2000) · New England Journal of Medicine · doi:10.1056/nejm200011163432003 · Cited by 3,306
Magnetic resonance imaging and cardiac pacemaker safety at 1.5-Tesla
Martin, E. T., Coman, J. A., Shellock, F. G., Pulling, C. C., Fair, R., & Jenkins, K. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.12.016 · Cited by 422
American College of Radiology White Paper on MR Safety
Kanal, E., Borgstede, J. P., Barkovich, A. J., Bell, C., Bradley, W. G., Felmlee, J. P., Froelich, J. W., Kaminski, E. M., Keeler, E. K., Lester, J. W., et al. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.178.6.1781335 · Cited by 282
Magnetic Resonance Imaging Determination of Cardiac Prognosis
Hundley, W. G., Morgan, T. M., Neagle, C. M., Hamilton, C. A., Rerkpattanapipat, P., & Link, K. M. (2002) · Circulation · doi:10.1161/01.cir.0000036017.46437.02 · Cited by 278
Effects of magnetic resonance imaging on cardiac pacemakers and electrodes
Achenbach, S. S., Moshage, W. E. L., Diem, B., Bieberlea, T., Schibgilla, V., & Bachmann, K. F. (1997) · American Heart Journal · doi:10.1016/s0002-8703(97)70083-8 · Cited by 254
MR Imaging and Cardiac Pacemakers: In Vitro Evaluation and in Vivo Studies in 51 Patients at 0.5 T
Sommer, T., Vahlhaus, C., Lauck, G., Smekal, A. V., Reinke, M., Hofer, U., Block, W., Träber, F., Schneider, C., Gieseke, J., et al. (2000) · Radiology · doi:10.1148/radiology.215.3.r00jn08869 · Cited by 244
Interference in Implanted Cardiac Devices, Part II
Pinski, S. L., & Trohman, R. G. (2002) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2002.01496.x · Cited by 132
MR imaging-related heating of deep brain stimulation electrodes: in vitro study.
Finelli, D. A., Rezai, A. R., Ruggieri, P. M., Tkach, J. A., Nyenhuis, J. A., Hrdlicka, G., Sharan, A. D., Gonzalez-Martinez, J. A., Stypulkowski, P. H., & Shellock, F. G. (2002) · PubMed Central · Cited by 125
Electromagnetic interference in patients with implanted pacemakers or cardioverter-defibrillators
NIEHAUS, M., & Tebbenjohanns, J. (2001) · Heart · doi:10.1136/heart.86.3.246 · Cited by 115
Interference in implanted cardiac devices--Part II.
Irnich, W. E. (2003) · PubMed · Cited by 114
Vahlhaus, C., Sommer, T., Lewalter, T., Schimpf, R., Schumacher, B. M., Jung, W., & Lüderitz, B. (2001) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2001.00489.x · Cited by 102
Gimbel, J., & Kanal, E. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.02.009 · Cited by 98
MR Safety and the American College of Radiology White Paper
Shellock, F. G., & Crues, J. V. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.178.6.1781349 · Cited by 90
Implantable Cardioverter Defibrillator Dysfunction During and After Magnetic Resonance Imaging
Anfinsen, O., Berntsen, R. F., Aass, H., Kongsgaard, E., & Amlie, J. (2002) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2002.01400.x · Cited by 63
Thermal Responses in Human Subjects Exposed to Magnetic Resonance Imaginga
Shellock, F. G. (1992) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1992.tb49615.x · Cited by 40
Cited by
WRITING COMMITTEE MEMBERS, Hundley, W. G., Bluemke, D. A., Finn, J. P., Flamm, S. D., Fogel, M. A., Friedrich, M. G., Ho, V. B., Jerosch-Herold, M., Kramer, C. M., et al. (2010) · Circulation · doi:10.1161/cir.0b013e3181d44a8f · Cited by 821
Self-citationACCF/ACR/AHA/NASCI/SCMR 2010 Expert Consensus Document on Cardiovascular Magnetic Resonance
Hundley, W. G., Bluemke, D. A., Finn, J. P., Flamm, S. D., Fogel, M. A., Friedrich, M. G., Ho, V. B., Jerosch-Herold, M., Kramer, C. M., Manning, W. J., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.11.011 · Cited by 593
Self-citationLevine, G. N., Gomes, A. S., Arai, A. E., Bluemke, D. A., Flamm, S. D., Kanal, E., Manning, W. J., Martin, E. T., Smith, J. M., Wilke, N., et al. (2007) · Circulation · doi:10.1161/circulationaha.107.187256 · Cited by 489
Self-citationIndik, J. H., Gimbel, J. R., Abe, H., Alkmim-Teixeira, R., Birgersdotter-Green, U., Clarke, G. D., Dickfeld, T.-M. L., Froelich, J. W., Grant, J., Hayes, D. L., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.04.025 · Cited by 438
Self-citationCurrent Clinical Issues for MRI Scanning of Pacemaker and Defibrillator Patients
KALIN, R., & STANTON, M. S. (2005) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2005.50024.x · Cited by 381
Metadata
- Authors
- Roguin, A., Zviman, M. M., Meininger, G. R., Rodrigues, E. R., Dickfeld, T. M., Bluemke, D. A., Lardo, A., Berger, R. D., Calkins, H., & Halperin, H. R.
- Venue
- Circulation
- Published
- 2004-08-03
- Volume
- 110
- Issue
- 5
- Pages
- 475-482
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2164605113
- Cited by
- 355
- References
- 15
- FWCI
- 18.59
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.