Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 309

The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.

Continuous Autonomic Assessment in Patients With Symptomatic Heart Failure: Prognostic Value of Heart Rate Variability Measured by an Implanted Cardiac Resynchronization Device

Adamson, Philip B., Smith, Andrew L., Abraham, William T., Kleckner, Karen J., Stadler, Robert W., Shih, Alex, Rhodes, Melissa M. · 2004 · Circulation

Abstract

Background— Heart rate variability (HRV) as an indirect autonomic assessment provides prognostic information when measured over short time periods in patients with heart failure. Long-term continuous HRV can be measured from an implantable device, but the clinical value of these measurements is unknown. Methods and Results— A total of 397 patients with New York Heart Association class III or IV heart failure were studied. Of these, 370 patients had information from their implanted cardiac resynchronization device for mortality risk stratification, and 288 patients had information for measured parameters (ie, HRV, night heart rate, and patient activity) and clinical event analyses. Continuous HRV was measured as the standard deviation of 5-minute median atrial-atrial intervals (SDAAM) sensed by the device. SDAAM <50 ms when averaged over 4 weeks was associated with increased mortality risk (hazard ratio 3.20, P =0.02) and SDAAM were persistently lower over the entire follow-up period in patients who required hospitalization or died. SDAAM decreased a median of 16 days before hospitalization and returned to baseline after treatment. Automated detection of decreases in SDAAM was 70% sensitive in detecting cardiovascular hospitalization, with 2.4 false-positives per patient-year of follow-up. Conclusions— This study demonstrates that SDAAM continuously measured from an implanted cardiac resynchronization device is lower in patients at high mortality and hospitalization risk. SDAAM declines as patient status decompensates. Continuous long-term SDAAM may be a useful tool in the clinical management of patients with chronic heart failure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.0000139841.42454.78

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 21 references

Cited by

See all 309

Metadata

Authors
Adamson, P. B., Smith, A. L., Abraham, W. T., Kleckner, K. J., Stadler, R. W., Shih, A., & Rhodes, M. M.
Venue
Circulation
Published
2004-10-19
Volume
110
Issue
16
Pages
2389-2394
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2125202987
Cited by
309
References
21
FWCI
10.33
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Continuous Autonomic Assessment in Patients With Symptomatic Heart Failure: Prognostic Value of Heart Rate Variability Measured by an Implanted Cardiac Resynchronization Device. https://app.cochat.ai/papers/10.1161/01.cir.0000139841.42454.78
The paper
Adamson, P. B., Smith, A. L., Abraham, W. T., Kleckner, K. J., Stadler, R. W., Shih, A., & Rhodes, M. M. (2004). Continuous Autonomic Assessment in Patients With Symptomatic Heart Failure: Prognostic Value of Heart Rate Variability Measured by an Implanted Cardiac Resynchronization Device. Circulation. https://doi.org/10.1161/01.cir.0000139841.42454.78

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.