The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Left Ventricular Assist Device as Destination for Patients Undergoing Intravenous Inotropic Therapy: A Subset Analysis From REMATCH (Randomized Evaluation of Mechanical Assistance in Treatment of Chronic Heart Failure)
Open accessAbstract
Background— Left ventricular assist devices (LVADs) have improved survival in patients with end-stage heart failure. Compared with previous trials, the Randomized Evaluation of Mechanical Assistance in Treatment of Chronic Heart Failure (REMATCH) trial enrolled patients with more advanced heart failure and high prevalence of intravenous inotropic therapy. This study analyzes, on a post hoc basis, outcomes in patients undergoing inotropic infusions at randomization. Methods and Results— Of 129 patients randomized, 91 were receiving intravenous inotropic therapy at randomization to LVAD or optimal medical management (OMM). Mean systolic pressure was 100 versus 107 mm Hg in those not receiving inotropes, serum sodium was 134 versus 137 mEq/L, and left ventricular ejection fraction was 17% for both groups. LVADs improved survival throughout follow-up for patients undergoing baseline inotropic infusions ( P =0.0014); for the LVAD group versus the OMM group, respectively, 6-month survival was 60% versus 39%, 1-year survival rates were 49% versus 24%, and 2-year survival rates were 28% versus 11%. For 38 patients not undergoing inotropic infusions, 6-month survival was 61% for those with LVADs and 67% for those with OMM, whereas 1-year rates were 57% and 40%, respectively ( P =0.55). Quality-of-life scores for survivors improved. Median days out of hospital for patients on inotropic therapy at randomization were 255 with LVAD and 105 with OMM. Conclusions— Despite severe compromise, patients undergoing inotropic infusions at randomization derived major LVAD survival benefit with improved quality of life. Patients not undergoing inotropic infusions had higher survival rates both with and without LVAD, but differences did not reach significance. Future studies should prespecify analyses of inotropic and other therapies to determine how disease severity and parallel medical treatment influence the benefits offered by mechanical circulatory support.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Effect of Spironolactone on Morbidity and Mortality in Patients with Severe Heart Failure
Pitt, B., Zannad, F., Remme, W. J., Cody, R., Castaigne, A., Perez, A., Palensky, J., & Wittes, J. (1999) · New England Journal of Medicine · doi:10.1056/nejm199909023411001 · Cited by 9,214
The SOLVD Investigators* (1991) · New England Journal of Medicine · doi:10.1056/nejm199108013250501 · Cited by 8,029
Cardiac Resynchronization in Chronic Heart Failure
Abraham, W. T., Fisher, W. G., Smith, A. L., Delurgio, D. B., Leon, A. R., Loh, E., Kocovic, D. Z., Packer, M., Clavell, A. L., Hayes, D. L., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013168 · Cited by 4,648
Effect of carvedilol on survival in severe chronic heart failure
Packer, M., Coats, A. J. S., Fowler, M. B., Katus, H. A., Krum, H., Mohacsi, P., Rouleau, J. L., Tendera, M., Castaigne, A., Roecker, E. B., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejm200105313442201 · Cited by 3,093
Cited by
2013 ACCF/AHA Guideline for the Management of Heart Failure
Yancy, C. W., Jessup, M., Bozkurt, B., Butler, J., Casey, D. E., Drazner, M. H., Fonarow, G. C., Geraci, S. A., Horwich, T., Januzzi, J. L., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.05.019 · Cited by 12,536
Self-citationYancy, C. W., Jessup, M., Bozkurt, B., Butler, J., Casey, D. E., Drazner, M. H., Fonarow, G. C., Geraci, S. A., Horwich, T., Januzzi, J. L., et al. (2013) · Circulation · doi:10.1161/cir.0b013e31829e8807 · Cited by 3,304
Self-citationPeberdy, M. A., Callaway, C. W., Neumar, R. W., Geocadin, R. G., Zimmerman, J. L., Donnino, M., Gabrielli, A., Silvers, S. M., Zaritsky, A. L., Merchant, R., et al. (2010) · Circulation · doi:10.1161/circulationaha.110.971002 · Cited by 2,522
Yancy, C. W., Jessup, M., Bozkurt, B., Butler, J., Casey, D. E., Drazner, M. H., Fonarow, G. C., Geraci, S. A., Horwich, T., Januzzi, J. L., et al. (2013) · Circulation · doi:10.1161/cir.0b013e31829e8776 · Cited by 2,106
Self-citationFeldman, D., Pamboukian, S. V., Teuteberg, J. J., Birks, E., Lietz, K., Moore, S. A., Morgan, J. A., Arabia, F., Bauman, M. E., Buchholz, H. W., et al. (2013) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2012.09.013 · Cited by 1,368
Metadata
- Authors
- Stevenson, L. W., Miller, L. W., Desvigne-Nickens, P., Ascheim, D. D., Parides, M. K., Renlund, D. G., Oren, R. M., Krueger, S. K., Costanzo, M. R., Wann, L. S., Levitan, R. G., & Mancini, D.
- Venue
- Circulation
- Published
- 2004-08-24
- Volume
- 110
- Issue
- 8
- Pages
- 975-981
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2160476190
- Cited by
- 206
- References
- 4
- FWCI
- 14.89
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Left Ventricular Assist Device as Destination for Patients Undergoing Intravenous Inotropic Therapy: A Subset Analysis From REMATCH (Randomized Evaluation of Mechanical Assistance in Treatment of Chronic Heart Failure). https://app.cochat.ai/papers/10.1161/01.cir.0000139862.48167.23
- The paper
- Stevenson, L. W., Miller, L. W., Desvigne-Nickens, P., Ascheim, D. D., Parides, M. K., Renlund, D. G., Oren, R. M., Krueger, S. K., Costanzo, M. R., Wann, L. S., Levitan, R. G., & Mancini, D. (2004). Left Ventricular Assist Device as Destination for Patients Undergoing Intravenous Inotropic Therapy: A Subset Analysis From REMATCH (Randomized Evaluation of Mechanical Assistance in Treatment of Chronic Heart Failure). Circulation. https://doi.org/10.1161/01.cir.0000139862.48167.23
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.