Prevention of Sudden Death in Hypertrophic Cardiomyopathy: But Which Defibrillator for Which Patient?

Open access
Boriani, Giuseppe, Maron, Barry J., Shen, Win-Kuang, Spirito, Paolo · 2004 · Circulation
Cited by 51

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

C ase presentation: A 14-year-old girl died suddenly and unexpectedly while exercising. Clinical and echocardiographic family screening identified hypertrophic cardiomyopathy (HCM) in her only sibling, an asymptomatic 17-year-old boy. In her brother, echocardiography showed extreme septal ventricular hypertrophy, 35 mm in thickness; left ventricular (LV) outflow obstruction was absent. Left atrial dimension was 42 mm. Holter monitoring showed 2 runs of nonsustained ventricular tachycardia (5 and 8 beats). Blood pressure response during exercise was normal. The patient was judged to be at high risk for sudden death and a candidate for an implantable cardioverter-defibrillator (ICD). The overall favorable clinical profile (ie, no symptoms, preserved systolic function, and low risk of developing atrial fibrillation [AF]) suggested that long-term survival principally relied on effective prevention of sudden death. Therefore, ICD selection centered on the long-term reliability of the ICD system, particularly the leads. A single-chamber ICD with a single-coil active-fixation lead was implanted to facilitate extraction should lead removal be required. Moreover, a high–shock output ICD was used because of the massive LV hypertrophy and possible high defibrillation threshold. During the past few years, interest has increased in the use of the ICD in genetic cardiac diseases associated with sudden cardiac death, such as HCM, long-QT syndrome, arrhythmogenic right ventricular cardiomyopathy, and Brugada syndrome.1,2 HCM is by far the most common of these cardiac conditions, with a prevalence of about 1:500 in the general population.3,4 Because most HCM patients at high risk for sudden death are young, with no or only mild symptoms and preserved systolic function, prevention of sudden death by the ICD may prolong life substantially in this disease and could offer a normal or near-normal life expectancy to many patients.1,4,5 Indeed, recent investigations have shown that the ICD is effective in preventing sudden death in HCM. …

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.0000144463.65977.c9

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 51

Metadata

Authors
Boriani, G., Maron, B. J., Shen, W.-K., & Spirito, P.
Venue
Circulation
Published
2004-10-12
Volume
110
Issue
15
Pages
e438-42
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2167105740
Cited by
51
References
1
FWCI
3.51
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Prevention of Sudden Death in Hypertrophic Cardiomyopathy: But Which Defibrillator for Which Patient? https://app.cochat.ai/papers/10.1161/01.cir.0000144463.65977.c9
The paper
Boriani, G., Maron, B. J., Shen, W.-K., & Spirito, P. (2004). Prevention of Sudden Death in Hypertrophic Cardiomyopathy: But Which Defibrillator for Which Patient? Circulation. https://doi.org/10.1161/01.cir.0000144463.65977.c9

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.