The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Placebo-Controlled, Randomized Clinical Trial of Azimilide for Prevention of Ventricular Tachyarrhythmias in Patients With an Implantable Cardioverter Defibrillator
Open accessAbstract
Background— Although implanted cardioverter defibrillators (ICDs) effectively treat sustained ventricular tachyarrhythmias, up to 50% of ICD recipients eventually require concomitant antiarrhythmic drug therapy to prevent symptomatic arrhythmia recurrences and hence reduce the number of device therapies. Methods and Results— A total of 633 ICD recipients were enrolled in a randomized, double-blind, placebo-controlled study to evaluate the effect of daily doses of 75 or 125 mg of azimilide on recurrent symptomatic ventricular tachyarrhythmias and ICD therapies. Total all-cause shocks plus symptomatic ventricular tachycardia (VT) terminated by antitachycardia pacing (ATP) were significantly reduced by azimilide, with relative risk reductions of 57% (hazard ratio [HR]=0.43, 95% CI 0.26 to 0.69, P =0.0006) and 47% (HR=0.53, 95% CI 0.34 to 0.83, P =0.0053) at 75- and 125-mg doses, respectively. The reductions in all-cause shocks with both doses of azimilide did not achieve statistical significance. The incidence of all appropriate ICD therapies (shocks or ATP-terminated VT) was reduced significantly among patients taking 75 mg of azimilide (HR=0.52, 95% CI 0.30 to 0.89, P =0.017) and those taking 125 mg of azimilide (HR=0.38, 95% CI 0.22 to 0.65, P =0.0004). Five patients in the azimilide groups and 1 patient in the placebo group had torsade de pointes; all were successfully treated by the device. One patient taking 75 mg of azimilide had severe but reversible neutropenia. Conclusions— Azimilide significantly reduced the recurrence of VT or ventricular fibrillation terminated by shocks or ATP in ICD patients, thereby reducing the burden of symptomatic ventricular tachyarrhythmia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Azimilide also decreases ICD shocks, 29”
From Managing with pacemakers and implantable cardioverter defibrillators (2013) · cites this paper as [29]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moss, A. J., Zaręba, W., Hall, W. J., Klein, H., Wilber, D. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Brown, M. W., & Andrews, M. L. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013474 · Cited by 6,885
Self-citationCox’s regression model for counting processes: A large sample study
Andersen, P. K., & Gill, R. D. (1982) · The Annals of Statistics · doi:10.1214/aos/1176345976 · Cited by 4,419
Mortality and Morbidity in Patients Receiving Encainide, Flecainide, or Placebo
Echt, D. S., Liebson, P. R., Mitchell, L. B., Peters, R. W., Obias-Manno, D., Barker, A. H., Arensberg, D., Baker, A., Friedman, L., Greene, H. L., et al. (1991) · New England Journal of Medicine · doi:10.1056/nejm199103213241201 · Cited by 3,244
Meta-analysis of the implantable cardioverter defibrillator secondary prevention trials
Connolly, S. J. (2000) · European Heart Journal · doi:10.1053/euhj.2000.2476 · Cited by 1,138
Semiparametric regression for the mean and rate functions of recurrent events
Lin, D. Y., Wei, L. J., Yang, I., & Ying, Z. (2000) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/1467-9868.00259 · Cited by 969
Use of the Kolmogorov–Smirnov, Cramér–Von Mises and Related Statistics Without Extensive Tables
Stephens, M. A. (1970) · Journal of the Royal Statistical Society Series B (Statistical Methodology) · doi:10.1111/j.2517-6161.1970.tb00821.x · Cited by 582
CONTROLLED TRIAL OF SOTALOL FOR ONE YEAR AFTER MYOCARDIAL INFARCTION
Julian, D. G., Jackson, F. S., Prescott, R. J., & Szekely, P. (1982) · The Lancet · doi:10.1016/s0140-6736(82)92225-5 · Cited by 430
Prevention of Implantable-Defibrillator Shocks by Treatment with Sotalol
Pacifico, A., Hohnloser, S. H., Williams, J. H., Tao, B., Saksena, S., Henry, P. D., & Prystowsky, E. N. (1999) · New England Journal of Medicine · doi:10.1056/nejm199906173402402 · Cited by 422
Self-citationElectrical Storm Presages Nonsudden Death
Exner, D. V., Pinski, S. L., Wyse, D. G., Renfroe, E. G., Follmann, D. A., Gold, M. R., Beckman, K. J., Coromilas, J., Lancaster, S. E., & Hallstrom, A. P. (2001) · Circulation · doi:10.1161/01.cir.103.16.2066 · Cited by 393
Electrical storm in patients with transvenous implantable cardioverter-defibrillators
Credner, S., Klingenheben, T., Mauß, O., Sticherling, C., & Hohnloser, S. H. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00495-1 · Cited by 375
Self-citationQuality of life in the Canadian Implantable Defibrillator Study (CIDS)
Irvine, J., Dorian, P., Baker, B., O'Brien, B. J., Roberts, R., Gent, M., Newman, D., & Connolly, S. J. (2002) · American Heart Journal · doi:10.1067/mhj.2002.124049 · Cited by 368
Self-citationImplantable Cardioverter–Defibrillators
Dimarco, J. (2003) · New England Journal of Medicine · doi:10.1056/nejmra035432 · Cited by 294
Risk Factors for Syncope Recurrence After a Positive Tilt-Table Test in Patients With Syncope
Sheldon, R. S., Rose, S., Flanagan, P., Koshman, M. L., & Killam, S. (1996) · Circulation · doi:10.1161/01.cir.93.5.973 · Cited by 231
Mortality in Patients After a Recent Myocardial Infarction
Camm, A. J., Pratt, C. M., Schwartz, P. J., Al‐Khalidi, H. R., Spyt, M. J., Holroyde, M. J., Karam, R., Sonnenblick, E. H., & Brum, J. M. (2004) · Circulation · doi:10.1161/01.cir.0000117090.01718.2a · Cited by 226
Self-citationEffectiveness of implantable defibrillators for preventing arrhythmic events and death
Lee, D. S., Green, L. D., Liu, P. P., Dorian, P., Newman, D. M., Grant, F., Tu, J. V., & Alter, D. A. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00253-5 · Cited by 195
Self-citationThe CASCADE study: Randomized antiarrhythmic drug therapy in survivors of Cardiac Arrest in Seattle
Greene, H. L., & The CASCADE Investigators (1993) · The American Journal of Cardiology · doi:10.1016/0002-9149(93)90966-g · Cited by 186
Long-Term Comparison of the Implantable Cardioverter Defibrillator Versus Amiodarone
Bokhari, F., Newman, D. M., Greene, M., Korley, V. J., Mangat, I., & Dorian, P. (2004) · Circulation · doi:10.1161/01.cir.0000134957.51747.6e · Cited by 180
Self-citationPérez‐Villacastín, J., Almendral, J. M., Arenal, Á., Albertos, J., Ormaetxe, J. M., Peinado, R., Bueno, H., Merino, J. L., Pastor, A., Medina, O., et al. (1996) · Circulation · doi:10.1161/01.cir.93.4.753 · Cited by 145
Greene, M. (2000) · EP Europace · doi:10.1053/eupc.2000.0104 · Cited by 136
Sample size for Poisson regression
Signorini, D. F. (1991) · Biometrika · doi:10.1093/biomet/78.2.446 · Cited by 119
Busch, A. E., Malloy, K., Groh, W. J., Varnum, M. D., Adelman, J. P., & Maylie, J. (1994) · Biochemical and Biophysical Research Communications · doi:10.1006/bbrc.1994.1922 · Cited by 94
Effect of sotalol on ventricular fibrillation and defibrillation in humans
Dorian, P., & Newman, D. M. (1993) · The American Journal of Cardiology · doi:10.1016/0002-9149(93)90028-b · Cited by 79
Self-citationSteinberg, J. S., Martins, J. B., Sadanandan, S., Goldner, B. G., Menchavez, E., DOMANSKI, M. J., Russo, A. M., Tullo, N. G., & Hallstrom, A. P. (2001) · American Heart Journal · doi:10.1067/mhj.2001.117129 · Cited by 76
Lee, K. L., Hafley, G. E., Fisher, J. D., Gold, M. R., Prystowsky, E. N., Talajic, M. R., Josephson, M. E., Packer, D. L., & Buxton, A. E. (2002) · Circulation · doi:10.1161/01.cir.0000021920.73149.c3 · Cited by 74
Singer, I., Al‐Khalidi, H. R., Niazi, I. K., TCHOU, P. J., Simmons, T. W., Henthorn, R. W., Holroyde, M. J., & Brum, J. M. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.07.033 · Cited by 72
Self-citationAdaptive Biased Urn Randomization in Small Strata When Blinding Is Impossible
Schouten, H. J. A. (1995) · Biometrics · doi:10.2307/2533283 · Cited by 62
Qi, X., Newman, D. M., & Dorian, P. (1999) · Journal of Interventional Cardiac Electrophysiology · doi:10.1023/a:1009879708404 · Cited by 36
Self-citationApplying Bayesian ideas to the development of medical guidelines
Landrum, M. B., & Normand, S. T. (1999) · Statistics in Medicine · doi:10.1002/(sici)1097-0258(19990130)18:2 · Cited by 32
Amiodarone and Defibrillation Thresholds:
Dorian, P. (2000) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2000.tb00044.x · Cited by 11
Self-citation
Cited by
Sorted by citations
Zipes, D. P., Camm, A. J., Borggrefe, M., Buxton, A. E., CHAITMAN, B. R., FROMER, M. A., Gregoratos, G., Klein, G. J., Myerburg, R. J., Quiñones, M. A., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.07.010 · Cited by 1,975
Self-citationZipes, D. P., Camm, A. J., Borggrefe, M., Buxton, A. E., Chaitman, B., Fromer, M., Gregoratos, G., Klein, G., Moss, A. J., Myerburg, R. J., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.178233 · Cited by 1,080
Self-citationZipes, D. P., Camm, A. J., Borggrefe, M., Buxton, A. E., CHAITMAN, B. R., FROMER, M. A., Gregoratos, G., Klein, G. J., Moss, A. J., Myerburg, R. J., et al. (2006) · EP Europace · doi:10.1093/europace/eul108 · Cited by 741
Self-citationGermano, J. J., Reynolds, M. R., Essebag, V., & Josephson, M. E. (2006) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2005.11.048 · Cited by 215
Hohnloser, S. H., Al‐Khalidi, H. R., Pratt, C. M., Brum, J. M., Tatla, D. S., TCHOU, P. J., Dorian, P., & on behalf of the SHock Inhibition Evaluation with AzimiLiDe (SHIELD) Investigators (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl276 · Cited by 192
Self-citation
Metadata
- Authors
- Dorian, P., Borggrefe, M., Al-Khalidi, H. R., Hohnloser, S. H., Brum, J. M., Tatla, D. S., Brachmann, J., Myerburg, R. J., Cannom, D. S., van der Laan, M., Holroyde, M. J., Singer, I., & Pratt, C. M.
- Affiliations
- Goethe University Frankfurt (DE)
- From the Division of Cardiology, St. Michael’s Hospital (P.D.), Toronto, Ontario, Canada; Klinikum Mannheim (M.B.), Universtatsklinikum, Mannheim, Germany; Health Care Research Center (H.R.A.-K., J.M.B., D.S.T., M.J.H.), Procter & Gamble Pharmaceuticals, Cincinnati, Ohio; J.W. Goethe University (S.H.H.), Department of Cardiology, Division of Electrophysiology, Frankfurt, Germany; Landkrankenhaus Coburg (J.B.), II Medizinische Klinik, Coburg, Germany; University of Miami School of Medicine (R.J.M...
- Venue
- Circulation
- Published
- 2004-12-14
- Volume
- 110
- Issue
- 24
- Pages
- 3646-3654
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2147134314
- Cited by
- 155
- References
- 29
- Citations by year
- 2025: 3 · 2024: 1 · 2022: 2 · 2021: 2 · 2020: 2 · 2019: 6 · 2018: 5 · 2017: 10 · 2016: 6 · 2015: 4 · 2014: 3 · 2013: 14 · 2012: 6
- FWCI
- 9.46
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Circulation (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
- Keywords
- azimilide, implantable cardioverter-defibrillator, ventricular tachyarrhythmia, antiarrhythmic drugs, arrhythmia recurrence prevention, ICD shocks, antitachycardia pacing, ventricular fibrillation, torsades de pointes, neutropenia, dose comparison
- MeSH terms
- Anti-Arrhythmia Agents, Double-Blind Method, Electric Countershock, Female, Humans, Hydantoins, Male, Middle Aged, Piperazines, Defibrillators, Implantable, Tachycardia, Ventricular, Endpoint Determination, Imidazolidines, Secondary Prevention
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review