Randomized Trial of High Loading Dose of Clopidogrel for Reduction of Periprocedural Myocardial Infarction in Patients Undergoing Coronary Intervention: Results From the ARMYDA-2 (Antiplatelet therapy for Reduction of MYocardial Damage during Angioplasty) Study

Patti, Giuseppe, Colonna, Giuseppe, Pasceri, Vincenzo, Pepe, Leonardo Lassandro, Montinaro, Antonio, Di Sciascio, Germano·2005·Circulation

Abstract

Background— Aggressive platelet inhibition is crucial to reduce myocardial injury and early cardiac events after coronary intervention. Although observational data have suggested that pretreatment with a high loading dose of clopidogrel may be more effective than a conventional dose, this hypothesis has never been tested in a randomized trial. Methods and Results— A total of 255 patients scheduled to undergo percutaneous coronary intervention were randomized to a 600-mg (n=126) or 300-mg (n=129) loading regimen of clopidogrel given 4 to 8 hours before the procedure. Creatine kinase MB, troponin I, and myoglobin levels were measured at baseline and at 8 and 24 hours after intervention. The primary end point was the 30-day occurrence of death, myocardial infarction (MI), or target vessel revascularization. The primary end point occurred in 4% of patients in the high loading dose versus 12% of those in the conventional loading dose group ( P =0.041) and was due entirely to periprocedural MI. Peak values of all markers were significantly lower in patients treated with the 600-mg regimen ( P ≤0.038). Safety end points were similar in the 2 arms. At multivariable analysis, the high loading regimen was associated with a 50% risk reduction of MI (OR 0.48, 95% CI 0.15 to 0.97, P =0.044). An incremental benefit was observed in patients randomized to the 600-mg dose who were receiving statins, with an 80% risk reduction. Conclusions— Pretreatment with a 600-mg loading dose of clopidogrel 4 to 8 hours before the procedure is safe and, as compared with the conventional 300-mg dose, significantly reduced periprocedural MI in patients undergoing percutaneous coronary intervention. These results may influence practice patterns with regard to antiplatelet therapy before percutaneous revascularization.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.0000161383.06692.d4

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 652

Metadata

Authors
Patti, G., Colonna, G., Pasceri, V., Pepe, L. L., Montinaro, A., & Di Sciascio, G.
Venue
Circulation
Published
2005-04-26
Volume
111
Issue
16
Pages
2099-2106
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2041936661
Cited by
652
References
0
FWCI
50.70
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Randomized Trial of High Loading Dose of Clopidogrel for Reduction of Periprocedural Myocardial Infarction in Patients Undergoing Coronary Intervention: Results From the ARMYDA-2 (Antiplatelet therapy for Reduction of MYocardial Damage during Angioplasty) Study. https://app.cochat.ai/papers/10.1161/01.cir.0000161383.06692.d4
The paper
Patti, G., Colonna, G., Pasceri, V., Pepe, L. L., Montinaro, A., & Di Sciascio, G. (2005). Randomized Trial of High Loading Dose of Clopidogrel for Reduction of Periprocedural Myocardial Infarction in Patients Undergoing Coronary Intervention: Results From the ARMYDA-2 (Antiplatelet therapy for Reduction of MYocardial Damage during Angioplasty) Study. Circulation. https://doi.org/10.1161/01.cir.0000161383.06692.d4

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.