Four-Year Angiographic and Intravascular Ultrasound Follow-Up of Patients Treated With Sirolimus-Eluting Stents
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Background— Despite the proven superiority of sirolimus-eluting stents (SESs) compared with bare stents in the first year after implantation, long-term outcomes of patients treated with these novel devices remain unknown. Our goal was to evaluate the clinical, angiographic, and intravascular ultrasound (IVUS) outcomes of patients treated with SESs 4 years after implantation. Methods and Results— The study included 30 patients treated with sirolimus-eluting Bx Velocity stenting (slow release [SR; n=15] and fast release [FR; n=15]). Twenty-six patients underwent 4-year angiographic and IVUS follow-up and had matched assessments at all time points (index and 4-, 12-, 24-, and 48-month follow-up). One death occurred during the study period in a patient with a patent SES. There were no target-vessel revascularizations or thromboses between 2- and 4-year follow-up examinations. There was no stent thrombosis, target-lesion revascularization, death, or myocardial infarction in the SR group up to 4 years. Cumulative event-free survival rate was 87% for the total population (80% in the FR group and 93% in the SR group). In-stent late loss was slightly greater in the FR group (0.41±0.49 mm) than the SR group (0.09±0.23) after 4 years. One patient in the FR group had a 52% in-stent restenosis lesion. Percent neointimal hyperplasia volume, as detected by IVUS, remained minimal after 4 years (FR=9.1% and SR=5.7%). Conclusions— This study confirms the longevity of the optimal outcomes observed in patients treated with sirolimus-eluting Bx Velocity stents 4 years after implantation. In-stent lumen dimensions remained essentially unchanged at 4-year follow-up, particularly in the population treated with the currently available SES (SR formulation).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Serruys, P. W., de Jaegere, P., Kiemeneij, F., Macaya, C., Rutsch, W., Heyndrickx, G., Emanuelsson, H., Marco, J., Legrand, V., Materne, P., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310801 · Cited by 4,556
Self-citationMoses, J. W., Leon, M. B., Popma, J. J., Fitzgerald, P. J., Holmes, D. R., O'Shaughnessy, C., Caputo, R. P., Kereiakes, D. J., Williams, D. O., Teirstein, P. S., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa035071 · Cited by 4,224
Self-citationMorice, M.-C., Serruys, P. W., Sousa, J. E., Fajadet, J., Ban Hayashi, E., Perin, M., Colombo, A., Schuler, G., Barragan, P., Guagliumi, G., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa012843 · Cited by 4,033
Self-citationColombo, A., Drzewiecki, J., Banning, A., Grube, E., Hauptmann, K., Silber, S., Dudek, D., Fort, S., Schiele, F., Zmudka, K., et al. (2003) · Circulation · doi:10.1161/01.cir.0000086926.62288.a6 · Cited by 1,016
New Frontiers in Cardiology: Drug-Eluting Stents: Part I
Sousa, J. E., Serruys, P. W., & Costa, M. A. (2003) · Circulation · doi:10.1161/01.cir.0000069330.41022.90 · Cited by 349
Self-citationLemos, P. A., Saia, F., Ligthart, J. M. R., Arampatzis, C. A., Sianos, G., Tanabe, K., Hoye, A., Degertekin, M., Daemen, J., McFadden, E., et al. (2003) · Circulation · doi:10.1161/01.cir.0000083366.33686.11 · Cited by 286
Self-citationFirst human experience with the 17-beta-estradiol–eluting stent
Abizaid, A., Albertal, M., Costa, M. A., Abizaid, A. S., Staico, R., Feres, F., Mattos, L. A., Sousa, A. G. M. R., Moses, J. W., Kipshidize, N., et al. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.01.023 · Cited by 85
Self-citation
Cited by
Serruys, P. W., Kutryk, M. J. B., & Ong, A. T. L. (2006) · New England Journal of Medicine · doi:10.1056/nejmra051091 · Cited by 762
Self-citationHemodialysis Vascular Access Dysfunction: A Cellular and Molecular Viewpoint
Roy-Chaudhury, P., Sukhatme, V. P., & Cheung, A. K. (2006) · Journal of the American Society of Nephrology · doi:10.1681/asn.2005050615 · Cited by 584
Decellularized tissue-engineered blood vessel as an arterial conduit
Quint, C., Kondo, Y., Manson, R. J., Lawson, J. H., Dardik, A., & Niklason, L. E. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1019506108 · Cited by 368
Lee, M. S., Kapoor, N., Jamal, F., Czer, L., Aragon, J., Forrester, J., Kar, S., Dohad, S., Kass, R., Eigler, N., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.09.072 · Cited by 348
Nakazawa, G., Finn, A. V., Vorpahl, M., Ladich, E. R., Kolodgie, F. D., & Virmani, R. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.05.066 · Cited by 299
Metadata
- Authors
- Sousa, J. E., Costa, M. A., Abizaid, A., Feres, F., Seixas, A. C., Tanajura, L. F., Mattos, L. A., Falotico, R., Jaeger, J., Popma, J. J., Serruys, P. W., & Sousa, A. G. M. R.
- Venue
- Circulation
- Published
- 2005-05-10
- Volume
- 111
- Issue
- 18
- Pages
- 2326-2329
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2102358305
- Cited by
- 181
- References
- 7
- FWCI
- 25.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.