Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 239

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Screening of Obstructive Sleep Apnea Syndrome by Heart Rate Variability Analysis

Roche, Frédéric, Gaspoz, Jean-Michel, Court-Fortune, Isabelle, Minini, Pascal, Pichot, Vincent, Duverney, David, Costes, Frédéric, Lacour, Jean-René, Barthélémy, Jean-Claude·1999·Circulation

Abstract

Background —Enhanced nocturnal heart rate variability (HRV) has been evoked in sleep-related breathing disorders. However, its capacity to detect obstructive sleep apnea syndrome (OSAS) has not been systematically determined. Thus, we evaluated the discriminant power of HRV parameters in a first group of patients (G1) and validated their discriminant capacity in a second group (G2). Methods and Results —In G1, 39 of 91 patients (42.8%) were identified as diseased by polysomnography, as were 24 of 52 patients (46%) in G2. Time-domain HRV variables (SD of NN intervals [SDNN], mean of the standard deviations of all NN intervals for all consecutive 5-minute segments of the recording [SDNN index], square root of the mean of the sum of the squares of differences between adjacent normal RR intervals [r-MSSD], and SD of the averages of NN intervals in all 5-minute segments of the recording [SDANN]) were calculated for daytime and nighttime periods, as well as the differences between daytime and nighttime values (Δ[D/N]). Correlations between HRV variables and OSAS status were analyzed in G1 by use of receiver-operating characteristic (ROC) curves and logistic regression analysis. By ROC curve analysis, 7 variables were significantly associated with OSAS. After adjustment for other variables through multiple logistic regression analysis, Δ[D/N]SDNN index and Δ[D/N] r-MSSD remained significant independent predictors of OSAS, with ORs of 8.22 (95% CI, 3.16 to 21.4) and 2.86 (95% CI, 1.21 to 6.75), respectively. The classification and regression tree methodology demonstrated a sensitivity reaching 89.7% (95% CI, 73.7 to 97.7) with Δ[D/N] SDNN index and a specificity of 98.1% (95% CI, 86.4 to 100) with Δ[D/N] SDNN using appropriate thresholds. These thresholds, applied to G2, yielded a sensitivity of 83% using Δ[D/N] SDNN index and a specificity of 96.5% using Δ[D/N] SDNN. Conclusions —Time-domain HRV analysis may represent an accurate and inexpensive screening tool in clinically suspected OSAS patients and may help focus resources on those at the highest risk.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.100.13.1411

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 239

Metadata

Authors
Roche, F., Gaspoz, J.-M., Court-Fortune, I., Minini, P., Pichot, V., Duverney, D., Costes, F., Lacour, J.-R., & Barthélémy, J.-C.
Venue
Circulation
Published
1999-09-28
Volume
100
Issue
13
Pages
1411-1415
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2139434612
Cited by
239
References
4
FWCI
2.08
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Screening of Obstructive Sleep Apnea Syndrome by Heart Rate Variability Analysis. https://app.cochat.ai/papers/10.1161/01.cir.100.13.1411
The paper
Roche, F., Gaspoz, J.-M., Court-Fortune, I., Minini, P., Pichot, V., Duverney, D., Costes, F., Lacour, J.-R., & Barthélémy, J.-C. (1999). Screening of Obstructive Sleep Apnea Syndrome by Heart Rate Variability Analysis. Circulation. https://doi.org/10.1161/01.cir.100.13.1411

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.