The DOI matches its Crossref record.
Utility of Fast Cine Magnetic Resonance Imaging and Display for the Detection of Myocardial Ischemia in Patients Not Well Suited for Second Harmonic Stress Echocardiography
Abstract
Background —Some patients referred for pharmacological stress testing with transthoracic echocardiography (TTE) are unable to undergo testing owing to poor acoustic windows. Fast cine MRI can be used to assess left ventricular contraction, but its utility for detection of myocardial ischemia in patients poorly suited for echocardiography is unknown. Methods and Results —One hundred fifty-three patients (86 men and 67 women aged 30 to 88 years) with poor acoustic windows that prevented adequate second harmonic TTE imaging were consecutively referred for MRI to diagnose inducible myocardial ischemia during intravenous dobutamine and atropine. Diagnostic studies were completed in an average of 53 minutes. No patients experienced myocardial infarction, ventricular fibrillation, exacerbation of congestive heart failure, or death. In patients who underwent computer-assisted quantitative coronary angiography, the sensitivity and specificity for detecting a >50% luminal diameter narrowing were 83% and 83%, respectively. In the 103 patients with a negative MRI examination, the cardiovascular occurrence–free survival rate was 97%. Conclusions —Fast cine cardiac MRI provides a mechanism to assess left ventricular contraction and diagnose inducible myocardial ischemia in patients not well suited for stress echocardiography.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
2013 ESC guidelines on the management of stable coronary artery disease
Task Force Members, Montalescot, G., Sechtem, U., Achenbach, S., Andreotti, F., Arden, C., Budaj, A., Bugiardini, R., Crea, F., Cuisset, T., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht296 · Cited by 4,510
Fihn, S. D., Gardin, J. M., Abrams, J., Berra, K., Blankenship, J. C., Dallas, A. P., Douglas, P. S., Foody, J. M., Gerber, T. C., Hinderliter, A. L., et al. (2012) · Circulation · doi:10.1161/cir.0b013e318277d6a0 · Cited by 845
Clinical indications for cardiovascular magnetic resonance (CMR): Consensus Panel report?
PENNELL, D. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.06.040 · Cited by 747
Fleisher, L. A., Beckman, J. A., Brown, K. A., Calkins, H., Chaikof, E. L., Fleischmann, K. E., Freeman, W. K., Froehlich, J. B., Kasper, E. K., Kersten, J. R., et al. (2007) · Circulation · doi:10.1161/circulationaha.107.185699 · Cited by 587
Metadata
- Authors
- Hundley, W. G., Hamilton, C. A., Thomas, M. S., Herrington, D. M., Salido, T. B., Kitzman, D. W., Little, W. C., & Link, K. M.
- Venue
- Circulation
- Published
- 1999-10-19
- Volume
- 100
- Issue
- 16
- Pages
- 1697-1702
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2005682987
- Cited by
- 332
- References
- 0
- FWCI
- 11.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Utility of Fast Cine Magnetic Resonance Imaging and Display for the Detection of Myocardial Ischemia in Patients Not Well Suited for Second Harmonic Stress Echocardiography. https://app.cochat.ai/papers/10.1161/01.cir.100.16.1697
- The paper
- Hundley, W. G., Hamilton, C. A., Thomas, M. S., Herrington, D. M., Salido, T. B., Kitzman, D. W., Little, W. C., & Link, K. M. (1999). Utility of Fast Cine Magnetic Resonance Imaging and Display for the Detection of Myocardial Ischemia in Patients Not Well Suited for Second Harmonic Stress Echocardiography. Circulation. https://doi.org/10.1161/01.cir.100.16.1697
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.