Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 188

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Electrophysiological Effects of Dronedarone (SR33589), a Noniodinated Benzofuran Derivative, in the Rabbit Heart: Comparison With Amiodarone

Open access
Sun, Wei, Sarma, Jonnalagedda S. M., Singh, Bramah N. · 1999 · Circulation

Abstract

Background —To overcome the side effects of amiodarone (AM), its noniodinated analogue, dronedarone (SR), was synthesized. In this study, its electrophysiological effects were compared with those of AM in rabbit hearts. Methods and Results —Five animal groups (n=7 each) for 3 weeks received daily oral treatment of 1 of these regimens: (1) control, vehicle only; (2) AM 50 mg/kg (AM50); (3) AM 100 mg/kg (AM100); (4) SR 50 mg/kg (SR50); and (5) SR 100 mg/kg (SR100). ECGs were recorded before drug and at 3 weeks of drug before euthanasia. Action potentials were recorded from isolated papillary muscle and sinoatrial node by microelectrode techniques. The short-term effects were studied in controls (n=5) at various concentrations of SR (0 to 10 μmol/L) in tissue bath. Action potential duration at 50% (APD 50 ) and 90% (APD 90 ) repolarization and upstroke dV/dt (V max ) at various cycle lengths were compared by ANOVA with repeated measures. Compared with control, AM and SR increased RR, QT, and QTc intervals ( P <0.0001 for all). Ventricular APD 50 and APD 90 were lengthened by 20% to 49% as a function of dose ( P <0.005 to <0.0001) and cycle length ( P <0.001). SR100 effects were greater than those of AM100 ( P <0.002). V max was decreased by both AM100 ( P <0.0001) and SR100 ( P <0.01). Sinoatrial node automaticity was slowed in treated groups compared with that of the control group ( P <0.0001 for all). Conclusions —The electrophysiological effects of dronedarone are similar to those of AM but more potent, despite deletion of iodine from its molecular structure, a finding of importance for the development of future class III antiarrhythmic compounds.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.100.22.2276

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 188

Metadata

Authors
Sun, W., Sarma, J. S. M., & Singh, B. N.
Venue
Circulation
Published
1999-11-30
Volume
100
Issue
22
Pages
2276-2281
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1998556131
Cited by
188
References
1
FWCI
6.11
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Electrophysiological Effects of Dronedarone (SR33589), a Noniodinated Benzofuran Derivative, in the Rabbit Heart: Comparison With Amiodarone. https://app.cochat.ai/papers/10.1161/01.cir.100.22.2276
The paper
Sun, W., Sarma, J. S. M., & Singh, B. N. (1999). Electrophysiological Effects of Dronedarone (SR33589), a Noniodinated Benzofuran Derivative, in the Rabbit Heart: Comparison With Amiodarone. Circulation. https://doi.org/10.1161/01.cir.100.22.2276

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.