Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 225

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Long-Term Follow-Up After Percutaneous Transluminal Coronary Angioplasty Was Not Performed Based on Intravascular Ultrasound Findings: Importance of Lumen Dimensions

Abizaid, Andrea S., Mintz, Gary S., Mehran, Roxana, Abizaid, Alexandre, Lansky, Alexandra J., Pichard, Augusto D., Satler, Lowell F., Wu, Hongsheng, Pappas, Chrysoula, Kent, Kenneth M., Leon, Martin B.·1999·Circulation

Abstract

Background —Angiography is limited in determining the anatomic severity of coronary artery stenoses. Clinical decision-making in patients with symptoms and intermediate lesions remains challenging. Methods and Results —The current analysis included 300 patients (357 intermediate native artery lesions) in whom intervention was deferred based on intravascular ultrasound (IVUS) findings. Standard clinical, angiographic, and IVUS parameters were collected. Patients were followed for >1 year. Events occurred in 24 patients (8%). They included 2 cardiac deaths, 4 myocardial infarctions, and 18 target-lesion revascularizations (TLR; 12 percutaneous transluminal coronary angiographies and 6 coronary artery bypass grafts; only 3 TLRs occurred within 6 months after the IVUS study). All significant univariate clinical, angiographic, and IVUS parameters ( P <0.05) were tested in multivariate models. These included diabetes mellitus, IVUS lesion lumen area, maximum lumen diameter, minimum lumen diameter, plaque area, plaque burden, and area stenosis (AS). No angiographic measurement was significant at P <0.05. The only independent predictors of an event (death, myocardial infarction, or TLR) were IVUS minimum lumen area and AS. The only independent predictors of TLR were diabetes mellitus, IVUS minimum lumen area, and AS. In 248 lesions with a minimum lumen area ≥4.0 mm 2 , the event rate was only 4.4% and the TLR rate 2.8%. Conclusions —Long-term follow-up after IVUS-guided deferred interventions in patients with de novo intermediate native artery lesions showed a low event rate. In patients with a minimum lumen area ≥4.0 mm 2 , the event rate was especially low. IVUS imaging is an acceptable alternative to physiological assessment in these patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.100.3.256

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 225

Metadata

Authors
Abizaid, A. S., Mintz, G. S., Mehran, R., Abizaid, A., Lansky, A. J., Pichard, A. D., Satler, L. F., Wu, H., Pappas, C., Kent, K. M., & Leon, M. B.
Venue
Circulation
Published
1999-07-20
Volume
100
Issue
3
Pages
256-261
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2105774427
Cited by
225
References
3
FWCI
7.14
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Long-Term Follow-Up After Percutaneous Transluminal Coronary Angioplasty Was Not Performed Based on Intravascular Ultrasound Findings: Importance of Lumen Dimensions. https://app.cochat.ai/papers/10.1161/01.cir.100.3.256
The paper
Abizaid, A. S., Mintz, G. S., Mehran, R., Abizaid, A., Lansky, A. J., Pichard, A. D., Satler, L. F., Wu, H., Pappas, C., Kent, K. M., & Leon, M. B. (1999). Long-Term Follow-Up After Percutaneous Transluminal Coronary Angioplasty Was Not Performed Based on Intravascular Ultrasound Findings: Importance of Lumen Dimensions. Circulation. https://doi.org/10.1161/01.cir.100.3.256

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.