Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 239

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Pathological Effects of Extensive Radiofrequency Energy Applications in the Pulmonary Veins in Dogs

Open access
Taylor, Gregg W., Kay, G. Neal, Zheng, Xiangsheng, Bishop, Sanford, Ideker, Raymond E. · 2000 · Circulation

Abstract

Introduction —The long-term complications of catheter ablation within the pulmonary veins are unknown. The development of pulmonary vein stenosis has recently been described after catheter ablation to treat either chronic or paroxysmal atrial fibrillation. The purpose of this study was to examine the pathological and hemodynamic effects of radiofrequency (RF) energy application within the pulmonary veins. Methods and Results —Right heart and transseptal catheterization were performed in 9 anesthetized mongrel dogs. The pulmonary vein ostia were cannulated and pulmonary venous pressure was measured before RF energy application in up to 4 separate pulmonary veins. Animals were euthanized at intervals of 2 to 4 weeks (n=3), 6 to 8 weeks (n=3), or 10 to 14 weeks (n=3) after ablation. Repeat catheterization before euthanasia demonstrated statistically significant differences in pulmonary capillary wedge pressure, cardiac output, pulmonary vascular resistance, and systemic vascular resistance ( P <0.05) compared with the baseline. Luminal narrowing was observed in 22 of 33 pulmonary veins to which RF energy was applied. Of these, 7 were totally occluded, 7 had severe stenosis, and 8 were only minimally narrowed. Histological examination revealed intimal proliferation with organizing thrombus, necrotic myocardium in various stages of collagen replacement, endovascular contraction, and a proliferation of elastic lamina. Conclusions —Applications of RF current within the pulmonary veins may result in pulmonary vein narrowing or complete occlusion. These observations should be considered in treatment of arrhythmias originating within the pulmonary veins.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.101.14.1736

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 239

Metadata

Authors
Taylor, G. W., Kay, G. N., Zheng, X., Bishop, S., & Ideker, R. E.
Venue
Circulation
Published
2000-04-11
Volume
101
Issue
14
Pages
1736-1742
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1988001586
Cited by
239
References
1
FWCI
6.58
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Pathological Effects of Extensive Radiofrequency Energy Applications in the Pulmonary Veins in Dogs. https://app.cochat.ai/papers/10.1161/01.cir.101.14.1736
The paper
Taylor, G. W., Kay, G. N., Zheng, X., Bishop, S., & Ideker, R. E. (2000). Pathological Effects of Extensive Radiofrequency Energy Applications in the Pulmonary Veins in Dogs. Circulation. https://doi.org/10.1161/01.cir.101.14.1736

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.