Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 725

The DOI matches its Crossref record.

Stable Microreentrant Sources as a Mechanism of Atrial Fibrillation in the Isolated Sheep Heart

Mandapati, Ravi, Skanes, Allan, Chen, Jay, Berenfeld, Omer, Jalife, José·2000·Circulation

Abstract

Background —Atrial fibrillation (AF) has traditionally been described as aperiodic or random. Yet, ongoing sources of high-frequency periodic activity have recently been suggested to underlie AF in the sheep heart. Our objective was to use a combination of optical and bipolar electrode recordings to identify sites of periodic activity during AF and elucidate their mechanism. Methods and Results —AF was induced by rapid pacing in the presence of 0.1 to 0.5 μmol/L acetylcholine in 7 Langendorff-perfused sheep hearts. We used simultaneous optical mapping of the right and left atria (RA and LA) and frequency sampling of optical and bipolar electrode recordings (including a roving electrode) to identify sites having the highest dominant frequency (DF). Rotors were identified from optical recordings, and their rotation period, core area, and perimeter were measured. In all, 35 AF episodes were analyzed. Mean LA and RA DFs were 14.7±3.8 and 10.3±2.1 Hz, respectively. Spatiotemporal periodicity was seen in the LA during all episodes. In 5 of 7 experiments, a single site having periodic activity at the highest DF was localized. The highest DF was most often (80%) localized to the posterior LA, near or at the pulmonary vein ostium. Rotors (n=14) were localized on the LA. The mean core perimeter and area were 10.4±2.8 mm and 3.8±2.8 mm 2 , respectively. Conclusions —Frequency sampling allows rapid identification of discrete sites of high-frequency periodic activity during AF. Stable microreentrant sources are the most likely underlying mechanism of AF in this model.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.101.2.194

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 725

Metadata

Authors
Mandapati, R., Skanes, A., Chen, J., Berenfeld, O., & Jalife, J.
Venue
Circulation
Published
2000-01-18
Volume
101
Issue
2
Pages
194-199
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2033891898
Cited by
725
References
0
FWCI
12.69
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Stable Microreentrant Sources as a Mechanism of Atrial Fibrillation in the Isolated Sheep Heart. https://app.cochat.ai/papers/10.1161/01.cir.101.2.194
The paper
Mandapati, R., Skanes, A., Chen, J., Berenfeld, O., & Jalife, J. (2000). Stable Microreentrant Sources as a Mechanism of Atrial Fibrillation in the Isolated Sheep Heart. Circulation. https://doi.org/10.1161/01.cir.101.2.194

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.