Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 226

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Assessment of Myocardial Reperfusion by Intravenous Myocardial Contrast Echocardiography and Coronary Flow Reserve After Primary Percutaneous Transluminal Coronary Angiography in Patients With Acute Myocardial Infarction

Open access
Lepper, Wolfgang, Hoffmann, Rainer, Kamp, Otto, Franke, Andreas, de Cock, Carel C., Kühl, Harald P., Sieswerda, Gertjan T., Dahl, Jürgen vom, Janssens, Uwe, Voci, Paolo, Visser, Cees A., Hanrath, Peter · 2000 · Circulation

Abstract

Background —This study investigated whether the extent of perfusion defect determined by intravenous myocardial contrast echocardiography (MCE) in patients with acute myocardial infarction (AMI) treated by primary percutaneous transluminal coronary angioplasty (PTCA) relates to coronary flow reserve (CRF) for assessment of myocardial reperfusion and is predictive for left ventricular recovery. Methods and Results —Twenty-five patients with first AMI underwent intravenous MCE with NC100100 with intermittent harmonic imaging before PTCA and after 24 hours. MCE before PTCA defined the risk region and MCE at 24 hours the “no-reflow” region. The no-reflow region divided by the risk region determined the ratio to the risk region. CFR was assessed immediately after PTCA and 24 hours later. Left ventricular wall motion score indexes were calculated before PTCA and after 4 weeks. CFR at 24 hours defined a recovery (CFR ≥1.6; n=17) and a nonrecovery group (CFR <1.6; n=8). Baseline CFR did not differ between groups. MCE ratio to the risk region was smaller in the recovery group compared with the nonrecovery group (34±49% vs 81±46%, P =0.009). A ratio to the risk region of ≤50% defined an MCE reperfusion group. It was associated with improvement of CFR from 1.67±0.47 at baseline to 2.15±0.53 at 24 hours ( P <0.001) and of regional wall motion score index from 2.6±0.5 to 1.9±0.5 at 4 weeks ( P <0.001). Conclusions —Intravenous MCE can be used to define perfusion defects after AMI. Assessment of microcirculation by MCE corresponds to evaluation by CFR. Serial intravenous MCE has the potential to identify patients likely to have improved left ventricular function after AMI.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.101.20.2368

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 226

Metadata

Authors
Lepper, W., Hoffmann, R., Kamp, O., Franke, A., de Cock, C. C., Kühl, H. P., Sieswerda, G. T., Dahl, J. V., Janssens, U., Voci, P., Visser, C. A., & Hanrath, P.
Venue
Circulation
Published
2000-05-23
Volume
101
Issue
20
Pages
2368-2374
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2043001782
Cited by
226
References
1
FWCI
22.92
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Assessment of Myocardial Reperfusion by Intravenous Myocardial Contrast Echocardiography and Coronary Flow Reserve After Primary Percutaneous Transluminal Coronary Angiography in Patients With Acute Myocardial Infarction. https://app.cochat.ai/papers/10.1161/01.cir.101.20.2368
The paper
Lepper, W., Hoffmann, R., Kamp, O., Franke, A., de Cock, C. C., Kühl, H. P., Sieswerda, G. T., Dahl, J. V., Janssens, U., Voci, P., Visser, C. A., & Hanrath, P. (2000). Assessment of Myocardial Reperfusion by Intravenous Myocardial Contrast Echocardiography and Coronary Flow Reserve After Primary Percutaneous Transluminal Coronary Angiography in Patients With Acute Myocardial Infarction. Circulation. https://doi.org/10.1161/01.cir.101.20.2368

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.