Cited by 309Signaling Pathways in DiseaseCardiac Fibrosis and RemodelingCardiovascular Function and Risk Factors

Cardiac hypertrophy is not a required compensatory response to short-term pressure overload

Hill, Joseph A., Karimi, Mohsen, Kutschke, William, Davisson, Robin L., Zimmerman, Kathy, Wang, Zhengyi, Kerber, Richard E., Weiss, Robert M.·2000·Circulation

Abstract

Background —Cardiac hypertrophy is considered a necessary compensatory response to sustained elevations of left ventricular (LV) wall stress. Methods and Results —To test this, we inhibited calcineurin with cyclosporine (CsA) in the setting of surgically induced pressure overload in mice and examined in vivo parameters of ventricular volume and function using echocardiography. Normalized heart mass increased 45% by 5 weeks after thoracic aortic banding (TAB; heart weight/body weight, 8.3±0.9 mg/g [mean±SEM] versus 5.7±0.1 mg/g unbanded, P <0.05). Similar increases were documented in the cell-surface area of isolated LV myocytes. In mice subjected to TAB+CsA treatment, we observed complete inhibition of hypertrophy (heart weight/body weight, 5.2±0.3 mg/g at 5 weeks) and myocyte surface area (endocardial and epicardial fractions). The mice tolerated abolition of hypertrophy with no signs of cardiovascular compromise, and 5-week mortality was not different from that of banded mice injected with vehicle (TAB+Veh). Despite abolition of hypertrophy by CsA (LV mass by echo, 83±5 mg versus 83±2 mg unbanded), chamber size (end-diastolic volume, 33±6 μL versus 37±1 μL unbanded), and systolic ejection performance (ejection fraction, 97±2% versus 97±1% unbanded) were normal. LV mass differed significantly in TAB+Veh animals (103±5 mg, P <0.05), but chamber volume (end-diastolic volume, 44±6 μL), ejection fraction (92±2%), and transstenotic pressure gradients (70±14 mm Hg in TAB+Veh versus 77±11 mm Hg in TAB+CsA) were not different. Conclusions —In this experimental setting, calcineurin blockade with CsA prevented LV hypertrophy due to pressure overload. TAB mice treated with CsA maintain normal LV size and systolic function.

Integrity signals

Registry

Crossref · 10.1161/01.cir.101.24.2863

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

The citation lists haven’t been fetched yet

References 37 · Cited by 309

Authors
Hill, J. A., Karimi, M., Kutschke, W., Davisson, R. L., Zimmerman, K., Wang, Z., Kerber, R. E., & Weiss, R. M.
Affiliations
University of Iowa (US)
Venue
Circulation
Published
2000-06-20
Volume
101
Issue
24
Pages
2863-2869
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2071267729
Cited by
309
References
37
Citations by year
2026: 3 · 2024: 4 · 2023: 5 · 2022: 7 · 2021: 10 · 2020: 14 · 2019: 8 · 2018: 8 · 2017: 9 · 2016: 8 · 2015: 13 · 2014: 9 · 2013: 10 · 2012: 15
FWCI
4.94
Type
journal article
Language
en
Open access
closed
Locations
  • Circulation (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Signaling Pathways in Disease
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Fibrosis and Remodeling
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Function and Risk Factors
Keywords
cardiac hypertrophy, pressure overload, calcineurin inhibition, cyclosporine, left ventricular mass, left ventricular function, trans-stenotic pressure gradient
MeSH terms
Acute Disease, Adaptation, Physiological, Animals, Aorta, Thoracic, Echocardiography, Enzyme Inhibitors, Cardiomegaly, Hemodynamics, Hypertension, Ligation, Male, Mice, Inbred C57BL, Cyclosporine, Mice, Calcineurin Inhibitors

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review