The DOI matches its Crossref record.
Detection of Atrial Fibrillation and Flutter by a Dual-Chamber Implantable Cardioverter-Defibrillator
Open accessAbstract
Background—To distinguish prolonged episodes of atrial fibrillation (AF) that require cardioversion from self-terminating episodes that do not, an atrial implantable cardioverter-defibrillator (ICD) must be able to detect AF continuously for extended periods. The ICD should discriminate between atrial tachycardia/flutter (AT), which may be terminated by antitachycardia pacing, and AF, which requires cardioversion. Methods and Results—We studied 80 patients with AT/AF and ventricular arrhythmias who were treated with a new atrial/dual-chamber ICD. During a follow-up period lasting 6±2 months, we validated spontaneous, device-defined AT/AF episodes by stored electrograms in all patients. In 58 patients, we performed 80 Holter recordings with telemetered atrial electrograms, both to validate the continuous detection of AT/AF and to determine the sensitivity of the detection of AT/AF. Detection was appropriate in 98% of 132 AF episodes and 88% of 190 AT episodes (98% of 128 AT episodes with an atrial cycle length <300 ms). Intermittent sensing of far-field R waves during sinus tachycardia caused 27 inappropriate AT/AF detections; these detections lasted 2.6±2.0 minutes. AT/AF was detected continuously in 27 of 28 patients who had spontaneous episodes of AT/AF (96%). The device memory recorded 90 appropriate AT/AF episodes lasting >1 hour, for a total of 2697 hours of continuous detection of AT/AF. During Holter monitoring, the sensitivity of the detection of AT/AF (116 hours) was 100%; the specificity of the detection of non-AT/AF rhythms (1290 hours) was 99.99%. Of 166 appropriate episodes detected as AT, 45% were terminated by antitachycardia pacing. Conclusions—A new ICD detects AT/AF accurately and continuously. Therapy may be programmed for long-duration AT/AF, with a low risk of underdetection. Discrimination of AT from AF permits successful pacing therapy for a significant fraction of AT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
ACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.02.032 · Cited by 2,546
Glotzer, T. V., Hellkamp, A. S., Zimmerman, J., Sweeney, M. O., Yee, R., Marinchak, R., Cook, J., Paraschos, A., Love, J., Radoslovich, G., et al. (2003) · Circulation · doi:10.1161/01.cir.0000057981.70380.45 · Cited by 750
BOTTO, G. L., PADELETTI, L., SANTINI, M., CAPUCCI, A., GULIZIA, M., ZOLEZZI, F., FAVALE, S., MOLON, G., RICCI, R., BIFFI, M., et al. (2009) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2008.01320.x · Cited by 380
Turakhia, M. P., Ziegler, P. D., Schmitt, S. K., Chang, Y., Fan, J., Than, C. T., Keung, E. K., & Singer, D. E. (2015) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.114.003057 · Cited by 197
Charitos, E. I., Stierle, U., Ziegler, P. D., Baldewig, M., Robinson, D. R., Sievers, H.-H., & Hanke, T. (2012) · Circulation · doi:10.1161/circulationaha.112.098079 · Cited by 196
Metadata
- Authors
- Swerdlow, C. D., Schšls, W., Dijkman, B., Jung, W., Sheth, N. V., Olson, W. H., Gunderson, B. D., & Investigators, F. T. W. J. A.
- Venue
- Circulation
- Published
- 2000-02-29
- Volume
- 101
- Issue
- 8
- Pages
- 878-885
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1991929582
- Cited by
- 168
- References
- 0
- FWCI
- 11.52
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of Atrial Fibrillation and Flutter by a Dual-Chamber Implantable Cardioverter-Defibrillator. https://app.cochat.ai/papers/10.1161/01.cir.101.8.878
- The paper
- Swerdlow, C. D., Schšls, W., Dijkman, B., Jung, W., Sheth, N. V., Olson, W. H., Gunderson, B. D., & Investigators, F. T. W. J. A. (2000). Detection of Atrial Fibrillation and Flutter by a Dual-Chamber Implantable Cardioverter-Defibrillator. Circulation. https://doi.org/10.1161/01.cir.101.8.878
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.