Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 231

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Hemodialysis Impairs Endothelial Function via Oxidative Stress: Effects of Vitamin E–Coated Dialyzer

Open access
Miyazaki, Hiroshi, Matsuoka, Hidehiro, Itabe, Hiroyuki, Usui, Michiaki, Ueda, Seiji, Okuda, Seiya, Imaizumi, Tsutomu·2000·Circulation

Abstract

Background —Patients who undergo hemodialysis experience accelerated atherosclerosis and premature death. Recent evidence suggests that endothelial dysfunction proceeds to and exacerbates atherosclerosis. It remains unknown whether hemodialysis per se causes endothelial dysfunction. Methods and Results —We evaluated endothelial function estimated by flow-mediated vasodilation during reactive hyperemia using high-resolution ultrasound Doppler echocardiography before and after a single session in patients on maintenance hemodialysis. Several studies have shown that the imbalance between pro-oxidant and antioxidant activities in hemodialyzed patients results in high oxidative stress, which causes lipid peroxidation and endothelial injury. Accordingly, we investigated the effects of antioxidative modification during hemodialysis on endothelial function using a vitamin E–coated cellulose membrane dialyzer. Nonspecific endothelium-independent vasodilation was measured after administration of a sublingual glyceryl trinitrate spray (0.3 mg). A single session of hemodialysis by noncoated dialyzer impaired flow-mediated vasodilation ( P <0.05) associated with increased plasma levels of oxidized LDL ( P <0.05), an index of oxidative stress. Hemodialysis by vitamin E–coated membrane prevented dialysis-induced endothelial dysfunction and increases in oxidized LDL. Plasma levels of oxidized LDL were inversely correlated with the magnitudes of flow-mediated vasodilation ( r =−0.53, P < 0.001). Hemodialysis by noncoated or vitamin E–coated membrane did not affect glyceryl trinitrate–induced endothelium-independent vasodilation. Conclusions —Our findings indicate that hemodialysis per se impairs endothelial function, possibly by increasing oxidative stress.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.101.9.1002

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 231

Metadata

Authors
Miyazaki, H., Matsuoka, H., Itabe, H., Usui, M., Ueda, S., Okuda, S., & Imaizumi, T.
Venue
Circulation
Published
2000-03-07
Volume
101
Issue
9
Pages
1002-1006
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2091826616
Cited by
231
References
1
FWCI
10.34
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Hemodialysis Impairs Endothelial Function via Oxidative Stress: Effects of Vitamin E–Coated Dialyzer. https://app.cochat.ai/papers/10.1161/01.cir.101.9.1002
The paper
Miyazaki, H., Matsuoka, H., Itabe, H., Usui, M., Ueda, S., Okuda, S., & Imaizumi, T. (2000). Hemodialysis Impairs Endothelial Function via Oxidative Stress: Effects of Vitamin E–Coated Dialyzer. Circulation. https://doi.org/10.1161/01.cir.101.9.1002

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.