The DOI matches its Crossref record.
Chronic Unloading by Left Ventricular Assist Device Reverses Contractile Dysfunction and Alters Gene Expression in End-Stage Heart Failure
Abstract
Background —Left ventricular (LV) assist devices (LVADs) can improve contractile strength and normalize characteristics of the Ca 2+ transient in myocytes isolated from failing human hearts. The purpose of the present study was to determine whether LVAD support also improves contractile strength at different frequencies of contraction (the force-frequency relationship [FFR]) of intact myocardium and alters the expression of genes encoding for proteins involved in Ca 2+ handling. Methods and Results —The isometric FFRs of LV trabeculae isolated from 15 patients with end-stage heart failure were compared with those of 7 LVAD-supported patients and demonstrated improved contractile force at 1-Hz stimulation, with reversal of a negative FFR after LVAD implantation. In 20 failing hearts, Northern blot analysis for sarcoplasmic endoreticular Ca 2+ -ATPase subtype 2a (SERCA2a), the ryanodine receptor, and the sarcolemmal Na + -Ca 2+ exchanger was performed on LV tissue obtained before and after LVAD implantation. These paired data demonstrated an upregulation of all 3 genes after LVAD support. In tissue obtained from subsets of these patients, Western blot analysis was performed, and oxalate-supported Ca 2+ uptake by isolated sarcoplasmic reticular membranes was determined. Despite higher mRNA for all genes after LVAD support, only SERCA2a protein was increased. Functional significance of increased SERCA2a was confirmed by augmented Ca 2+ uptake by sarcoplasmic reticular membranes isolated from LVAD-supported hearts. Conclusions —LVAD support can improve contractile strength of intact myocardium and reverse the negative FFR associated with end-stage heart failure. The expression of genes encoding for proteins involved in Ca 2+ cycling is upregulated (reverse molecular remodeling), but only the protein content of SERCA2a is increased.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mechanisms and Models in Heart Failure: A Combinatorial Approach
Mann, D. L. (1999) · Circulation · doi:10.1161/01.cir.100.9.999 · Cited by 773
Wehrens, X. H. T., Lehnart, S. E., Reiken, S. R., & Marks, A. R. (2004) · Circulation Research · doi:10.1161/01.res.0000125626.33738.e2 · Cited by 623
Self-citationTackling heart failure in the twenty-first century
Mudd, J. O., & Kass, D. A. (2008) · Nature · doi:10.1038/nature06798 · Cited by 406
Crabtree, M. J., Smith, C. L., Lam, G., Goligorsky, M. S., & Gross, S. S. (2008) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00823.2007 · Cited by 213
Chaudhary, K. W., Rossman, E. I., Piacentino, V., Kenessey, A., Weber, C., Gaughan, J. P., Ojamaa, K., Klein, I., Bers, D. M., Houser, S. R., et al. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.05.049 · Cited by 95
Metadata
- Authors
- Heerdt, P. M., Holmes, J. W., Cai, B., Barbone, A., Madigan, J. D., Reiken, S., Lee, D. L., Oz, M. C., Marks, A. R., & Burkhoff, D.
- Venue
- Circulation
- Published
- 2000-11-28
- Volume
- 102
- Issue
- 22
- Pages
- 2713-2719
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2157460773
- Cited by
- 296
- References
- 0
- FWCI
- 14.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Chronic Unloading by Left Ventricular Assist Device Reverses Contractile Dysfunction and Alters Gene Expression in End-Stage Heart Failure. https://app.cochat.ai/papers/10.1161/01.cir.102.22.2713
- The paper
- Heerdt, P. M., Holmes, J. W., Cai, B., Barbone, A., Madigan, J. D., Reiken, S., Lee, D. L., Oz, M. C., Marks, A. R., & Burkhoff, D. (2000). Chronic Unloading by Left Ventricular Assist Device Reverses Contractile Dysfunction and Alters Gene Expression in End-Stage Heart Failure. Circulation. https://doi.org/10.1161/01.cir.102.22.2713
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.