Saline-Cooled Versus Standard Radiofrequency Catheter Ablation for Infarct-Related Ventricular Tachycardias
The DOI matches its Crossref record.
Abstract
Background —Saline cooling of the electrode during radiofrequency (RF) ablation increases lesion size in animal models. If cooled RF also increases lesion size in human infarcts, it should facilitate the termination of ventricular tachycardia (VT). Methods and Results —In 66 patients with VT due to prior infarction, 366 ablation sites, which were classified by entrainment and isolated potentials followed by ablation during VT with either standard RF energy (247 sites) or cooled RF (119 sites), were retrospectively reviewed to compare the efficacy for terminating VT. RF energy was applied at 259 isthmus sites, 62 bystander sites, 28 inner loop sites, and 17 outer loop sites. Compared with standard RF, cooled RF terminated VT more frequently at isthmus sites where an isolated potential was present (89% versus 54%, P =0.003), isthmus sites without an isolated potential (36% versus 21%, P =0.04), and at inner loop sites (60% versus 22%, P =0.04). Termination rates were similarly low for cooled and standard RF at bystander sites (14% versus 9%, P =0.56) and outer loop sites (13% versus 11%, P =0.93). Conclusions —Greater efficacy of cooled RF for terminating VT is consistent with the production of a larger lesion in human infarctions, which should facilitate successful ablation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Calkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.04.005 · Cited by 1,701
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-012-9672-7 · Cited by 1,675
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.016 · Cited by 1,456
Calkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Europace · doi:10.1093/europace/eum120 · Cited by 1,290
Metadata
- Authors
- Soejima, K., Delacretaz, E., Suzuki, M., Brunckhorst, C. B., Maisel, W. H., Friedman, P. L., & Stevenson, W. G.
- Venue
- Circulation
- Published
- 2001-04-10
- Volume
- 103
- Issue
- 14
- Pages
- 1858-1862
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2070299587
- Cited by
- 134
- References
- 0
- FWCI
- 6.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Saline-Cooled Versus Standard Radiofrequency Catheter Ablation for Infarct-Related Ventricular Tachycardias. https://app.cochat.ai/papers/10.1161/01.cir.103.14.1858
- The paper
- Soejima, K., Delacretaz, E., Suzuki, M., Brunckhorst, C. B., Maisel, W. H., Friedman, P. L., & Stevenson, W. G. (2001). Saline-Cooled Versus Standard Radiofrequency Catheter Ablation for Infarct-Related Ventricular Tachycardias. Circulation. https://doi.org/10.1161/01.cir.103.14.1858
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.