The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Noninvasive Quantification of Left-to-Right Shunt in Pediatric Patients: Phase-Contrast Cine Magnetic Resonance Imaging Compared With Invasive Oximetry
Abstract
Background —Blood flow can be quantified noninvasively by phase-contrast cine MRI (PC-MRI) in adults. Little is known about the feasibility of the method in children with congenital heart disease. Methods and Results —In 50 children (mean age 6.2 years, range 1.1 to 17.7 years) with an atrial- or ventricular-level shunt, blood flow rate in the great vessels was determined by PC-MRI, and the ratio of pulmonary to aortic flow (Q̇p/Q̇s) was compared with Q̇p/Q̇s by oximetry. We found a difference of 2% and a range of −20% to +26% (limits of agreement, mean±2 SD). In another 7 children with congenital heart disease but no cardiac shunting (mean age 7.9 years, range 1.3 to 13.5 years), Q̇p/Q̇s by PC-MRI was 1.02 (SD ±0.06). No difference between systemic venous and aortic flow volumes was found (range −17% to +20%, n=37). Blood flow through a secundum atrial septal defect as assessed by PC-MRI (n=24) overestimated the shunt compared with the difference between pulmonary and aortic flows. The mean difference between 3 repeated PC-MRI measurements in each location was 5.3% (SD ±4.0%, n=522), demonstrating good precision. The interobserver variability was low. The accuracy of PC-MRI was confirmed by in vitro experiments. Conclusions —Determination of Q̇p/Q̇s by PC-MRI in children is quick, safe, and reliable compared with oximetry. Systemic venous flow can be quantified by PC-MRI, whereas through-plane shunt measurement within an atrial septal defect is inaccurate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
In Vivo Validation of MR Velocity Imaging
Firmin, D. N., Nayler, G. L., Klipstein, R. H., Underwood, S. R., Rees, R. S. O., & Longmore, D. B. (1987) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198709000-00001 · Cited by 332
Powell, A. J., Maier, S. E., Chung, T., & Geva, T. (2000) · Pediatric Cardiology · doi:10.1007/s002469910014 · Cited by 207
Hundley, W. G., Li, H. F., Lange, R. A., Pfeifer, D. P., Meshack, B. M., Willard, J. E., Landau, C., Willett, D. L., Hillis, L. D., & Peshock, R. M. (1995) · Circulation · doi:10.1161/01.cir.91.12.2955 · Cited by 191
Arterial and venous blood flow: noninvasive quantitation with MR imaging.
Pelc, L. R., Pelc, N. J., Rayhill, S. C., Castro, L. J., Glover, G. H., Herfkens, R. J., Miller, D. C., & Jeffrey, R. B. (1992) · Radiology · doi:10.1148/radiology.185.3.1438767 · Cited by 173
Brenner, L. D., Caputo, G. R., Mostbeck, G., Steiman, D. M., Mc, D., Cheitlin, M. D., O'Sullivan, M., & Higgins, C. B. (1992) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(92)90384-y · Cited by 146
Blood Flow Measurement by Magnetic Resonance Imaging in Congenital Heart Disease
Powell, A., & Geva, T. (2000) · Pediatric Cardiology · doi:10.1007/s002469910007 · Cited by 112
Arheden, H., Holmqvist, C., Thilén, U., Hanséus, K., Björkhem, G., Pahlm, O., Laurin, S., & Ståhlberg, F. (1999) · Radiology · doi:10.1148/radiology.211.2.r99ma43453 · Cited by 67
Steinman, D. A., Ethier, C. R., & Rutt, B. K. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070214 · Cited by 65
Plow quantitation with echo‐planar phase‐contrast velocity mapping: In vitro and in vivo evaluation
Debatin, J. F., Leung, D. A., Wildermuth, S., Botnar, R. M., Felblinger, J., & McKinnon, G. C. (1995) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880050607 · Cited by 47
Cited by
WRITING COMMITTEE MEMBERS, Hundley, W. G., Bluemke, D. A., Finn, J. P., Flamm, S. D., Fogel, M. A., Friedrich, M. G., Ho, V. B., Jerosch-Herold, M., Kramer, C. M., et al. (2010) · Circulation · doi:10.1161/cir.0b013e3181d44a8f · Cited by 821
ACCF/ACR/AHA/NASCI/SCMR 2010 Expert Consensus Document on Cardiovascular Magnetic Resonance
Hundley, W. G., Bluemke, D. A., Finn, J. P., Flamm, S. D., Fogel, M. A., Friedrich, M. G., Ho, V. B., Jerosch-Herold, M., Kramer, C. M., Manning, W. J., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.11.011 · Cited by 593
Fratz, S., Chung, T., Greil, G. F., Samyn, M. M., Taylor, A. M., Valsangiacomo Buechel, E. R., Yoo, S.-J., & Powell, A. J. (2013) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-15-51 · Cited by 507
Markl, M., Kilner, P. J., & Ebbers, T. (2011) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-13-7 · Cited by 463
Cardiac catheterisation guided by MRI in children and adults with congenital heart disease
Razavi, R., Hill, D. L., Keevil, S. F., Miquel, M. E., Muthurangu, V., Hegde, S., Rhode, K., Barnett, M., van Vaals, J., Hawkes, D. J., et al. (2003) · The Lancet · doi:10.1016/s0140-6736(03)14956-2 · Cited by 336
Metadata
- Authors
- Beerbaum, P., Körperich, H., Barth, P., Esdorn, H., Gieseke, J., & Meyer, H.
- Venue
- Circulation
- Published
- 2001-05-22
- Volume
- 103
- Issue
- 20
- Pages
- 2476-2482
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2117538480
- Cited by
- 309
- References
- 12
- FWCI
- 4.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Noninvasive Quantification of Left-to-Right Shunt in Pediatric Patients: Phase-Contrast Cine Magnetic Resonance Imaging Compared With Invasive Oximetry. https://app.cochat.ai/papers/10.1161/01.cir.103.20.2476
- The paper
- Beerbaum, P., Körperich, H., Barth, P., Esdorn, H., Gieseke, J., & Meyer, H. (2001). Noninvasive Quantification of Left-to-Right Shunt in Pediatric Patients: Phase-Contrast Cine Magnetic Resonance Imaging Compared With Invasive Oximetry. Circulation. https://doi.org/10.1161/01.cir.103.20.2476
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.