Permanent Epicardial Pacing in Pediatric Patients: Seventeen Years of Experience and 1200 Outpatient Visits

Abstract

Background —The purpose of this study was to evaluate the long-term outcome of all pediatric epicardial pacing leads. Methods and Results —All epicardial leads and 1239 outpatient visits between January 1, 1983, and June 30, 2000, were retrospectively reviewed. Pacing and sensing thresholds were reviewed at implant, at 1 month, and at subsequent 6-month intervals. Lead failure was defined as the need for replacement or abandonment due to pacing or sensing problems, lead fracture, or phrenic/muscle stimulation. A total of 123 patients underwent 207 epicardial lead (60 atrial/147 ventricular, 40% steroid) implantations (median age at implant was 4.1 years [range 1 day to 21 years]). Congenital heart disease was present in 103 (84%) of the patients. Epicardial leads were followed for 29 months (range 1 to 207 months). The 1-, 2-, and 5-year lead survival was 96%, 90%, and 74%, respectively. Compared with conventional epicardial leads, both atrial and ventricular steroid leads had better stimulation thresholds 1 month after implantation; however, only ventricular steroid leads had improved chronic pacing thresholds (at 2 years: for steroid leads, 1.9 μJ [from 0.26 to 16 μJ]; for nonsteroid leads, 4.7 μJ [from 0.6 to 25 μJ]; P <0.01). Ventricular sensing was significantly better in steroid leads 1 month after lead implantation (at 2 years: for steroid leads, 8 mV [from 4 to 31 mV]; for nonsteroid leads, 4 mV [from 0.7 to 10 mV]; P <0.01). Neither congenital heart disease, lead implantation with a concomitant cardiac operation, age or weight at implantation, nor the chamber paced was predictive of lead failure. Conclusions —Steroid epicardial leads demonstrated relatively stable acute and chronic pacing and sensing thresholds. In this evaluation of >200 epicardial leads, lead survival was good, with steroid-eluting leads demonstrating results similar to those found with historical conventional endocardial leads.

Overview

Integrity signals

Registry

Crossref · 10.1161/01.cir.103.21.2585

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 26

  1. 10.1016/0002-9149(90)90816-J · DOI
  2. 10.1097/00007611-199307000-00014 · DOI
  3. Williams WG, Hesslein PS, Kormos R. Exit block in children with pacemakers. Pacing Clin Electrophysiol. 1986;4:478–489.
  4. 10.1016/0002-9149(88)91313-6 · DOI
  5. Beder SD Kuehl KS Hopkins RA et al. Precipitous exit block with epicardial steroid-eluting leads. Pacing Clin Electrophysiol. 1997;20(pt 2):2954–2957. · DOI
  6. 10.1111/j.1540-8159.1984.tb04887.x · DOI
  7. 10.1111/j.1540-8159.1988.tb05988.x · DOI
  8. 10.1016/S1010-7940(00)00364-X · DOI
  9. Lau YR Gillette PC Buckles DS et al. Actuarial survival of transvenous pacing leads in a pediatric population. Pacing Clin Electrophysiol. 1993;16(pt 1):1363–1367. · DOI
  10. 10.1111/j.1540-8159.1988.tb06331.x · DOI
  11. Figa FH McCrindle BW Bigras JL et al. Risk factors for venous obstruction in children with transvenous pacing leads. Pacing Clin Electrophysiol. 1997;20(pt 1):1902–1909. · DOI
  12. 10.1016/0735-1097(92)90108-Y · DOI
  13. 10.1016/S0003-4975(99)01053-X · DOI
  14. 10.1067/mtc.2001.113027 · DOI
  15. Hamilton RM Chiu C Gow RM et al. A comparison of two stab-on unipolar epicardial pacing leads in children. Pacing Clin Electrophysiol. 1997;20(pt 1):631–636. · DOI
  16. 10.1016/0002-8703(90)90094-E · DOI
  17. Old WD, Paulsen W, Lewis S, et al. Pacemaker lead induced tricuspid stenosis: diagnosed by Doppler echocardiography. Am Heart J. 1990;117:1105–1107.
  18. 10.1016/S0003-4975(99)00695-5 · DOI
  19. 10.1016/S0003-4975(98)01340-X · DOI
  20. 10.1055/s-2007-1013815 · DOI
  21. 10.1111/j.1540-8159.2000.tb00775.x · DOI
  22. 10.1111/j.1540-8159.1992.tb02905.x · DOI
  23. 10.1016/0002-8703(89)90408-0 · DOI
  24. Cutler NG Karpawich PP Cavitt D et al. Steroid-eluting epicardial pacing thresholds: 6-year experience of pacing thresholds in a growing pediatric population. Pacing Clin Electrophysiol. 1997;20(pt 1):2943–2948. · DOI
  25. 10.1111/j.1540-8159.1992.tb03118.x · DOI
  26. 10.1016/0003-4975(92)90439-B · DOI

Cited by

Sorted by citations

Metadata

Authors
Cohen, M. I., Bush, D. M., Vetter, V. L., Tanel, R. E., Wieand, T. S., Gaynor, J. W., & Rhodes, L. A.
Affiliations
Children's Hospital of Philadelphia (US)
Venue
Circulation
Published
2001-05-29
Volume
103
Issue
21
Pages
2585-2590
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2031626363
Cited by
213
References
0
Citations by year
2026: 5 · 2025: 9 · 2024: 11 · 2023: 6 · 2022: 5 · 2021: 7 · 2020: 6 · 2019: 3 · 2018: 9 · 2017: 10 · 2016: 8 · 2015: 6 · 2014: 8 · 2013: 10 · 2012: 13
FWCI
4.16
Type
journal article
Language
en
Open access
closed
Locations
  • Circulation (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Congenital Heart Disease Studies
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
Keywords
epicardial pacing leads, pediatric cardiac pacing, steroid-eluting leads, lead failure, pacing threshold, sensing threshold, lead survival, congenital heart disease, ventricular pacing, atrial pacing, phrenic nerve stimulation, lead fracture
MeSH terms
Adolescent, Adult, Child, Child, Preschool, Follow-Up Studies, Heart, Humans, Infant, Infant, Newborn, Pacemaker, Artificial, Vascular Diseases, Survival Rate, Treatment Outcome

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review