Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 210

The DOI matches its Crossref record.

Magnetic Resonance Characterization of the Peri-Infarction Zone of Reperfused Myocardial Infarction With Necrosis-Specific and Extracellular Nonspecific Contrast Media

Open access
Saeed, Maythem, Lund, Gunnar, Wendland, Michael F., Bremerich, Jens, Weinmann, Hanns-Joachim, Higgins, Charles B. · 2001 · Circulation

Abstract

Background —Because ischemically injured myocardium is frequently composed of viable and nonviable portions, a method to discriminate the two is useful for clinical management. Methods and Results —Ischemically injured myocardium was characterized with extracellular nonspecific (Gd-DTPA) and necrosis-specific (mesoporphyrin) MR contrast media in rats. Relaxation rates (R1) were measured on day 1 and day 2 by inversion-recovery echoplanar imaging. Spin-echo imaging was used to define contrast-enhanced regions and regional wall thickening. Gadolinium concentration, area at risk, and infarct size were measured at postmortem examination. ΔR1 ratio (ΔR1 myocardium /ΔR1 blood ) after administration of Gd-DTPA was greater in ischemically injured myocardium (1.20±0.15) than in normal myocardium (0.47±0.05, P <0.05), which was attributed to differences in gadolinium concentration and water content. The Gd-DTPA–enhanced region on day 2 was larger (32.8±0.9%) than true infarction as demonstrated by triphenyltetrazolium chloride (TTC) (24.6±1.4%, P <0.001, r =0.21). Bland-Altman analysis revealed that the Gd-DTPA–enhanced region overestimated true infarct size by 7.8±5.9%. On the other hand, the mesoporphyrin-enhanced region (26.9±1.8%, P =NS, r =0.87) and true infarct size were identical. The difference in the areas demarcated by the 2 agents is the peri-infarction. Systolic and diastolic MR images revealed no wall thickening in the mesoporphyrin-enhanced region (0.3±3.3%) but reduced thickening in the Gd-DTPA–enhanced rim (8.5±5.5%, P <0.05). Conclusions —The Gd-DTPA–enhanced region encompasses both viable and nonviable portions of the ischemically injured myocardium. The Gd-DTPA–enhanced area overestimated infarct size, but the mesoporphyrin-enhanced area matched true infarct size. The salvageable peri-infarction zone can be characterized with double-contrast–enhanced and functional MR imaging; the mismatched area of enhancement between the 2 agents shows residual wall thickening.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.103.6.871

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 210

Metadata

Authors
Saeed, M., Lund, G., Wendland, M. F., Bremerich, J., Weinmann, H.-J., & Higgins, C. B.
Venue
Circulation
Published
2001-02-13
Volume
103
Issue
6
Pages
871-876
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1989013354
Cited by
210
References
0
FWCI
14.02
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Magnetic Resonance Characterization of the Peri-Infarction Zone of Reperfused Myocardial Infarction With Necrosis-Specific and Extracellular Nonspecific Contrast Media. https://app.cochat.ai/papers/10.1161/01.cir.103.6.871
The paper
Saeed, M., Lund, G., Wendland, M. F., Bremerich, J., Weinmann, H.-J., & Higgins, C. B. (2001). Magnetic Resonance Characterization of the Peri-Infarction Zone of Reperfused Myocardial Infarction With Necrosis-Specific and Extracellular Nonspecific Contrast Media. Circulation. https://doi.org/10.1161/01.cir.103.6.871

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.