The DOI matches its Crossref record.
The Corrected Orthogonal Electrocardiogram and Vectorcardiogram in 510 Normal Men (Frank Lead System)
Open accessAbstract
Corrected orthogonal electrocardiographic records were taken from 510 normal male subjects. Their age ranged from 19 to 84 years. Data processing and analysis were performed by means of a digital computer. Measurements were taken from the three scalar orthogonal leads and from a variety of spatial vectors in a Cartesian reference frame. Main emphasis was put on series of instantaneous vectors of the QRS complex, the ST segment, and the T wave. In order to eliminate inter-individual variability in electrocardiographic wave durations, time normalization was applied by dividing QRS, ST, and T into equal parts in time. Results for instantaneous vectors were also obtained in absolute time at intervals of 0.01 second. In addition, time integrals, polar vectors, and Eigenvectors were determined for P, QRS, and T. Normal ranges were computed for both normally and abnormally distributed results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Recommendations for the Standardization and Interpretation of the Electrocardiogram
Kligfield, P., Gettes, L. S., Bailey, J. J., Childers, R., Deal, B. J., Hancock, E. W., van Herpen, G., Kors, J. A., Macfarlane, P., Mirvis, D. M., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.01.024 · Cited by 807
Kligfield (2007) · doi:10.1161/circulationaha.106.180200 · Cited by 802
Criteria for intraventricular conduction disturbances and pre-excitation
Willems, J. L., Robles de Medina, E. O., Bernard, R., Coumel, P., Fisch, C., Krikler, D., Mazur, N. A., Meijler, F. L., Mogensen, L., Moret, P., et al. (1985) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(85)80335-1 · Cited by 393
Spatial QRS-T angle predicts cardiac death in a general population
Kardys, I. (2003) · European Heart Journal · doi:10.1016/s0195-668x(03)00203-3 · Cited by 280
Pavri, B. B., Hillis, M. B., Subačius, H., Brumberg, G. E., Schaechter, A., Levine, J. H., & Kadish, A. (2008) · Circulation · doi:10.1161/circulationaha.107.733451 · Cited by 88
Metadata
- Authors
- DRAPER, H. W., PEFFER, C. J., STALLMANN, F. W., LITTMANN, D., & PIPBERGER, H. V.
- Venue
- Circulation
- Published
- 1964-12
- Volume
- 30
- Issue
- 6
- Pages
- 853-864
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1995185527
- Cited by
- 225
- References
- 0
- FWCI
- 11.25
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Corrected Orthogonal Electrocardiogram and Vectorcardiogram in 510 Normal Men (Frank Lead System). https://app.cochat.ai/papers/10.1161/01.cir.30.6.853
- The paper
- DRAPER, H. W., PEFFER, C. J., STALLMANN, F. W., LITTMANN, D., & PIPBERGER, H. V. (1964). The Corrected Orthogonal Electrocardiogram and Vectorcardiogram in 510 Normal Men (Frank Lead System). Circulation. https://doi.org/10.1161/01.cir.30.6.853
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.