Catheter Technique for Recording His Bundle Activity in Man
Open accessThe DOI matches its Crossref record.
Abstract
A technique for the routine recording of His bundle (H) activity in man using a bipolar or multipolar catheter is described. The recording catheter is inserted percutaneously, via the Seldinger method, into the right femoral vein and advanced fluoroscopically into the right atrium. Placement of the pre-formed curve at the catheter tip across the tricuspid valve in nine patients resulted in stable recordings of His bundle activity in successive cardiac cycles. Right atrial pacing resulted in progressive lengthening of the P-H interval with increasing frequency but the H to S-wave interval remained constant at all rates. Similar lengthening of the P-H interval was produced during atrial pacing when pressure was applied to the carotid sinus. The use of this recording technique in man will facilitate diagnostic interpretation of the electrocardiogram and can be used in various investigations of atrioventricular and intraventricular conduction in man.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Right Ventricular Dysplasia: A Report of 24 Adult Cases
Marcus, F. I., Fontaine, G. H., Guiraudon, G., Frank, R., Laurenceau, J. L., Malergue, C., & Grosgogeat, Y. (1982) · Circulation · doi:10.1161/01.cir.65.2.384 · Cited by 1,603
Electrical Stimulation of the Heart in Patients with Ventricular Tachycardia
WELLENS, H. J., SCHUILENBURG, R. M., & DURRER, D. (1972) · Circulation · doi:10.1161/01.cir.46.2.216 · Cited by 497
Recent advances in flexible sensors for wearable and implantable devices
Pang, C., Lee, C., & Suh, K. (2013) · Journal of Applied Polymer Science · doi:10.1002/app.39461 · Cited by 457
A Conformal, Bio-Interfaced Class of Silicon Electronics for Mapping Cardiac Electrophysiology
Viventi, J., Kim, D.-H., Moss, J. D., Kim, Y.-S., Blanco, J. A., Annetta, N., Hicks, A., Xiao, J., Huang, Y., Callans, D. J., et al. (2010) · Science Translational Medicine · doi:10.1126/scitranslmed.3000738 · Cited by 420
Wu, D., Denes, P., Amat-Y-Leon, F., Dhingra, R., Wyndham, C. R. C., Bauernfeind, R., Latif, P., & Rosen, K. M. (1978) · The American Journal of Cardiology · doi:10.1016/0002-9149(78)90856-1 · Cited by 389
Vijayaraman, P., Chung, M. K., Dandamudi, G., Upadhyay, G. A., Krishnan, K., Crossley, G., Bova Campbell, K., Lee, B. K., Refaat, M. M., Saksena, S., et al. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.06.017 · Cited by 350
“(12) are credited with developing the catheter-based approach in humans for recording the His bundle in 1969, which has essentially remained unchanged in the electrophysiology laboratory to date.”
BackgroundPatterns of Atrioventricular Conduction in the Human Heart
WIT, A. L., WEISS, M. B., BERKOWITZ, W. D., ROSEN, K. M., STEINER, C., & Damato, A. N. (1970) · Circulation Research · doi:10.1161/01.res.27.3.345 · Cited by 326
Self-citationArterial Baroreflexes in Humans
Mancia, G., & Mark, A. L. (1983) · Comprehensive Physiology · doi:10.1002/cphy.cp020320 · Cited by 292
Wolff-Parkinson-White syndrome and atrial fibrillation
Wellens, H. J., & Durrer, D. (1974) · The American Journal of Cardiology · doi:10.1016/0002-9149(74)90695-x · Cited by 283
Cardiovascular Effects of Therapeutic Doses of Tricyclic Antidepressants: A Review
Glassman, A. H. (1981) · Archives of General Psychiatry · doi:10.1001/archpsyc.1981.01780320095011 · Cited by 269
Narula, O. S., Scherlag, B. J., Samet, P., & Javier, R. P. (1971) · The American Journal of Medicine · doi:10.1016/0002-9343(71)90144-6 · Cited by 217
Self-citationSUNG, R. J., ELSER, B., & McALLISTER, R. G. (1980) · Annals of Internal Medicine · doi:10.7326/0003-4819-93-5-682 · Cited by 198
Wenckebach and Mobitz Type II A-V Block Due to Block Within the His Bundle and Bundle Branches
NARULA, O. S., & SAMET, P. (1970) · Circulation · doi:10.1161/01.cir.41.6.947 · Cited by 191
The Spectrum of Cardiac Defects in the Ehlers-Danlos Syndrome, Types I and III
LEIER, C. V., CALL, T. D., FULKERSON, P. K., & WOOLEY, C. F. (1980) · Annals of Internal Medicine · doi:10.7326/0003-4819-92-2-171 · Cited by 163
Clinical Cardiac Electrophysiology
Rankin, A. C., Quinn, F. R., & Rae, A. P. (2012) · Cardiac Arrhythmias and Mapping Techniques · doi:10.1007/978-0-85729-877-5_2 · Cited by 162
Localization of A-V conduction defects in man by recording of the his bundle electrogram
Narula, O. S., Cohen, L. S., Samet, P., Lister, J. W., Scherlag, B., & Hildner, F. J. (1970) · The American Journal of Cardiology · doi:10.1016/0002-9149(70)90583-7 · Cited by 161
Self-citationThe incidence of typical and atypical A-V Wenckebach periodicity
Denes, P., Levy, L., Pick, A., & Rosen, K. M. (1975) · American Heart Journal · doi:10.1016/0002-8703(75)90005-8 · Cited by 79
Effects of digitalis on ventricular myocardial and His-Purkinje refractoriness and reentry in man
Gomes, J. A. C., Dhatt, M. S., Akhtar, M., Carambas, C. R., Rubenson, D. S., & Damato, A. N. (1978) · The American Journal of Cardiology · doi:10.1016/0002-9149(78)90678-1 · Cited by 22
Self-citation
Metadata
- Authors
- SCHERLAG, B. J., LAU, S. H., HELFANT, R. H., BERKOWITZ, W. D., STEIN, E., & DAMATO, A. N.
- Venue
- Circulation
- Published
- 1969-01
- Volume
- 39
- Issue
- 1
- Pages
- 13-18
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1989793815
- Cited by
- 1,037
- References
- 0
- FWCI
- 53.92
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.