The DOI matches its Crossref record.
Critical Assessment of Use of Central Venous Oxygen Saturation as a Mirror of Mixed Venous Oxygen in Severely Ill Cardiac Patients
Open accessAbstract
Bedside catheterization of the right heart with a percutaneously introduced flowdirected catheter was carried out in 24 critically ill patients; 71 determinations of mixed venous oxygen saturation (MVo 2 ) were obtained. A second catheter was inserted either into a central intrathoracic vein or the right atrium for simultaneous sampling of central venous (CVo 2 ) or right atrial (RAo 2 ) oxygen saturation. For the group as a whole, mean CVo 2 (57.9% ± 15.25) was significantly greater than mean MVo 2 (53.3% ± 14.84) ( P <0.001), but there was no significant difference and correlation was good between changes in central venous compared to changes in mixed venous oxygen saturation. On the other hand, there was no significant mean difference as well as an excellent correlation between individual values of RAo 2 and MVo 2 (r=+0.95). Patients with heart failure or shock showed poor correlation between CVo 2 and simultaneously determined MVo 2 . Furthermore, subjects with shock showed a mean CVo 2 (58.0%±13.05) that was significantly greater than mean MVo 2 (47.5% ± 15.11). In contrast, there was no significant difference between mean RAo 2 and mean MVo 2 and excellent correlation of individual values in patients with either heart failure or shock. Although CVo 2 is a poor reflection of MVo 2 in subjects with severe heart failure or shock, there was a better correlation between changes in CVo 2 with corresponding changes in MVo 2 . In addition, RAo 2 correlated closely with corresponding values of MVo 2 . The reversal of the normal relationship between CVo 2 and MVo 2 under these circumstances is compatible with the thesis that low output states are attended by redistribution of blood flow away from femoral, splanchnic, and renal circulation with preferential preservation of cerebral blood flow.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Early goal-directed therapy in the treatment of severe sepsis and septic shock
Rivers, E., Nguyen, B., Havstad, S., Ressler, J., Muzzin, A., Knoblich, B., Peterson, E., & Tomlanovich, M. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa010307 · Cited by 10,743
Reinhart, K., Rudolph, T., Bredle, D. L., Hannemann, L., & Cain, S. M. (1989) · Chest · doi:10.1378/chest.95.6.1216 · Cited by 515
Continuous central venous and pulmonary artery oxygen saturation monitoring in the critically ill
Reinhart, K., Kuhn, H.-J., Hartog, C., & Bredle, D. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2337-y · Cited by 437
de Oliveira, C. F., de Oliveira, D. S. F., Gottschald, A. F. C., Moura, J. D. G., Costa, G. A., Ventura, A. C., Fernandes, J. C., Vaz, F. A. C., Carcillo, J. A., Rivers, E. P., et al. (2008) · Intensive Care Medicine · doi:10.1007/s00134-008-1085-9 · Cited by 400
Nguyen, H. B., Rivers, E. P., Abrahamian, F. M., Moran, G. J., Abraham, E., Trzeciak, S., Huang, D. T., Osborn, T., Stevens, D., & Talan, D. A. (2006) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2006.02.015 · Cited by 356
Metadata
- Authors
- SCHEINMAN, M. M., BROWN, M. A., & RAPAPORT, E.
- Venue
- Circulation
- Published
- 1969-08
- Volume
- 40
- Issue
- 2
- Pages
- 165-172
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2131269210
- Cited by
- 228
- References
- 0
- FWCI
- 20.52
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Critical Assessment of Use of Central Venous Oxygen Saturation as a Mirror of Mixed Venous Oxygen in Severely Ill Cardiac Patients. https://app.cochat.ai/papers/10.1161/01.cir.40.2.165
- The paper
- SCHEINMAN, M. M., BROWN, M. A., & RAPAPORT, E. (1969). Critical Assessment of Use of Central Venous Oxygen Saturation as a Mirror of Mixed Venous Oxygen in Severely Ill Cardiac Patients. Circulation. https://doi.org/10.1161/01.cir.40.2.165
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.