Measurement of Coronary Sinus Blood Flow by Continuous Thermodilution in Man

GANZ, WILLIAM, TAMURA, KOHJI, MARCUS, HAROLD S., DONOSO, ROBERTO, YOSHIDA, SHINJI, SWAN, HAROLD J. C.·1971·Circulation

Abstract

A technique was developed for measurement of blood flow in the coronary sinus in man by continuous thermodilution. For single determinations, 5% dextrose at room temperature is injected at a constant rate of 35 ml/min for a period of about 20 sec. In 14 subjects with normal coronary arteries the mean coronary sinus blood flow was 122 ± 25 ml/min (range, 83 to 159 ml/min). The blood flow computed per 100 g of left ventricle was 82 ± 16 ml/min, which is in the range of values obtained by nitrous oxide and coincidence counting methods. In 35 patients with arteriographically confirmed coronary artery disease the mean flow was similar (128 ± 20 ml/min; range, 92 to 167 ml/min). A special catheter was used for simultaneous measurement of blood flow in the coronary sinus and great cardiac vein. In eight normal subjects the mean great cardiac vein flow was 68 ± 11 ml/min (range, 51 to 78 ml/min) or 65 ± 10% of the coronary sinus blood flow. The method allowed continuous measurement of flow over a period of several minutes and, for the first time, measurement of rapid changes in myocardial perfusion.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.44.2.181

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 961

Metadata

Authors
GANZ, W., TAMURA, K., MARCUS, H. S., DONOSO, R., YOSHIDA, S., & SWAN, H. J. C.
Venue
Circulation
Published
1971-08
Volume
44
Issue
2
Pages
181-195
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2055103382
Cited by
961
References
0
FWCI
19.86
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Measurement of Coronary Sinus Blood Flow by Continuous Thermodilution in Man. https://app.cochat.ai/papers/10.1161/01.cir.44.2.181
The paper
GANZ, W., TAMURA, K., MARCUS, H. S., DONOSO, R., YOSHIDA, S., & SWAN, H. J. C. (1971). Measurement of Coronary Sinus Blood Flow by Continuous Thermodilution in Man. Circulation. https://doi.org/10.1161/01.cir.44.2.181

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.