The DOI matches its Crossref record.
Comparison of Ultrasound and Cineangiographic Measurements of the Mean Rate of Circumferential Fiber Shortening in Man
Abstract
It has been shown that cineangiographic measurement of the mean rate of circumferential fiber shortening (mean V CF ) at the minor left ventricular equator is a reliable method for evaluating the mechanics of cardiac performance. Since fiber shortening can be derived from the echocardiogram, we sought to validate the measurement of mean V CF by this noninvasive technic in patients studied by both methods. In 15 patients considered to have normal left ventricular function, the average mean V CF determined by ultrasound was 1.29 ± 0.23 circumferences/sec, while in the 13 patients with reduced left ventricular performance this value was 0.75 ± 0.16 circumferences/sec ( P < 0.001). Values of mean V CF by the two technics were similar and separated normal from abnormal ventricular function in 27 of 28 patients. The average mean velocity of posterior wall motion was 4.7 ± 1.1 cm/sec in normal patients and 3.9 ± 1.3 cm/sec in abnormals, but posterior wall velocities did not correlate well with either ultrasound or cineangiographic determinations of mean V CF . Ejection fraction calculated from ultrasound measurements correlated significantly with the ejection fraction calculated by cineangiography (r = 0.83, P < 0.0001). The ejection fraction and mean V CF , as determined by ultrasound in the 28 patients, correlated well (r = 0.92, P < 0.0001), but there were six discordant points. From these studies we conclude that the ultrasound determination of mean V CF is a valid method for distinguishing normal from abnormal myocardial performance of the left ventricle. These data also support the use of ultrasound in determining ejection fraction. Estimation of posterior wall velocity, although perhaps useful in the serial study of the same patient, seems limited in its ability to assess cardiac performance accurately.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cardiac effects of prolonged and intense exercise training in patients with coronary artery disease
Ehsani, A. A., Martin, W. H., Heath, G. W., & Coyle, E. F. (1982) · The American Journal of Cardiology · doi:10.1016/0002-9149(82)90173-4 · Cited by 128
Echocardiographic Evaluation of Cardiac Performance
DiSessa, T. G., & Friedman, W. F. (1983) · Cardiology Clinics · doi:10.1016/s0733-8651(18)30791-4 · Cited by 11
Metadata
- Authors
- COOPER, R. H., O'ROURKE, R. A., KARLINER, J. S., PETERSON, K. L., & LEOPOLD, G. R.
- Venue
- Circulation
- Published
- 1972-11
- Volume
- 46
- Issue
- 5
- Pages
- 914-923
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1967152349
- Cited by
- 225
- References
- 0
- FWCI
- 16.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of Ultrasound and Cineangiographic Measurements of the Mean Rate of Circumferential Fiber Shortening in Man. https://app.cochat.ai/papers/10.1161/01.cir.46.5.914
- The paper
- COOPER, R. H., O'ROURKE, R. A., KARLINER, J. S., PETERSON, K. L., & LEOPOLD, G. R. (1972). Comparison of Ultrasound and Cineangiographic Measurements of the Mean Rate of Circumferential Fiber Shortening in Man. Circulation. https://doi.org/10.1161/01.cir.46.5.914
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.