Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 225

The DOI matches its Crossref record.

Comparison of Ultrasound and Cineangiographic Measurements of the Mean Rate of Circumferential Fiber Shortening in Man

COOPER, RONALD H., O'ROURKE, ROBERT A., KARLINER, JOEL S., PETERSON, KIRK L., LEOPOLD, GEORGE R.·1972·Circulation

Abstract

It has been shown that cineangiographic measurement of the mean rate of circumferential fiber shortening (mean V CF ) at the minor left ventricular equator is a reliable method for evaluating the mechanics of cardiac performance. Since fiber shortening can be derived from the echocardiogram, we sought to validate the measurement of mean V CF by this noninvasive technic in patients studied by both methods. In 15 patients considered to have normal left ventricular function, the average mean V CF determined by ultrasound was 1.29 ± 0.23 circumferences/sec, while in the 13 patients with reduced left ventricular performance this value was 0.75 ± 0.16 circumferences/sec ( P < 0.001). Values of mean V CF by the two technics were similar and separated normal from abnormal ventricular function in 27 of 28 patients. The average mean velocity of posterior wall motion was 4.7 ± 1.1 cm/sec in normal patients and 3.9 ± 1.3 cm/sec in abnormals, but posterior wall velocities did not correlate well with either ultrasound or cineangiographic determinations of mean V CF . Ejection fraction calculated from ultrasound measurements correlated significantly with the ejection fraction calculated by cineangiography (r = 0.83, P < 0.0001). The ejection fraction and mean V CF , as determined by ultrasound in the 28 patients, correlated well (r = 0.92, P < 0.0001), but there were six discordant points. From these studies we conclude that the ultrasound determination of mean V CF is a valid method for distinguishing normal from abnormal myocardial performance of the left ventricle. These data also support the use of ultrasound in determining ejection fraction. Estimation of posterior wall velocity, although perhaps useful in the serial study of the same patient, seems limited in its ability to assess cardiac performance accurately.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.46.5.914

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 225

Metadata

Authors
COOPER, R. H., O'ROURKE, R. A., KARLINER, J. S., PETERSON, K. L., & LEOPOLD, G. R.
Venue
Circulation
Published
1972-11
Volume
46
Issue
5
Pages
914-923
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1967152349
Cited by
225
References
0
FWCI
16.97
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of Ultrasound and Cineangiographic Measurements of the Mean Rate of Circumferential Fiber Shortening in Man. https://app.cochat.ai/papers/10.1161/01.cir.46.5.914
The paper
COOPER, R. H., O'ROURKE, R. A., KARLINER, J. S., PETERSON, K. L., & LEOPOLD, G. R. (1972). Comparison of Ultrasound and Cineangiographic Measurements of the Mean Rate of Circumferential Fiber Shortening in Man. Circulation. https://doi.org/10.1161/01.cir.46.5.914

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.