The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Myocardial Necrosis from Direct Current Countershock: Effect of Paddle Electrode Size and Time Interval Between Discharges
Abstract
The effect of varying both paddle electrode size and the time interval between direct current countershock on myocardial necrosis was studied. Forty-two dogs were divided into seven groups of six dogs each. All dogs were given ten consecutive, 240 watt-second countershocks (delivered energy into a 50 ohm load). Three groups were shocked with paddle electrode diameters of 8.0 cm (standard electrodes), two groups with paddle electrode diameters of 12.8 cm (large electrodes), and two groups with paddle electrode diameters of 4.3 cm (small electrodes). The time intervals between discharges in the groups shocked with the standard electrodes were 15 seconds, one minute, and three minutes. The time interval between discharges in the groups shocked with small and large electrodes was 15 seconds and three minutes. Myocardial necrosis was quantitated by precordial electrocardiographic mapping recorded minutes after, and by gross and microscopic examination of the hearts four days after direct current countershock. When the time interval between discharges was shorter, myocardial necrosis was greater. When the time interval between discharges was constant, more necrosis was produced with smaller-sized paddle electrodes. It is concluded that large paddle electrodes should be used for delivering direct current countershocks, and that during elective cardioversion, consecutive discharges should be delivered at time intervals greater than three minutes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Complications and Limitations of Direct-Current Countershock
Rabbino, M. D., LIKOFF, W. B., & Dreifus, L. S. (1964) · JAMA · doi:10.1001/jama.1964.03070180015003 · Cited by 128
Connell, P. N., Ewy, G. A., Dahl, C. F., & Ewy, M. D. (1973) · Journal of Electrocardiology · doi:10.1016/s0022-0736(73)80053-6 · Cited by 83
Self-citationDIRECT CURRENT COUNTERSHOCK COMPLICATIONS
Åberg, H. E., & Cullhed, I. (1968) · Acta Medica Scandinavica · doi:10.1111/j.0954-6820.1968.tb10501.x · Cited by 75
Cited by
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., Lowe, J. E., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.177292 · Cited by 2,805
ACC/AHA/ESC guidelines for the management of patients with atrial fibrillation: executive summary
Fuster, V., Rydén, L. E., Asinger, R. W., Cannom, D. S., Crijns, H. J., Frye, R. L., Halperin, J. L., Kay, G. N., Klein, W. W., Lévy, S., et al. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01587-x · Cited by 1,348
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Kay, G. N., Le Huezey, J.-Y., Lowe, J. E., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.09.013 · Cited by 924
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Kay, G. N., Le Huezey, J.-Y., Lowe, J. E., et al. (2011) · Circulation · doi:10.1161/cir.0b013e318214876d · Cited by 859
Writing Committee Members, Fuster, V., Ryden, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., et al. (2006) · Europace · doi:10.1093/europace/eul097 · Cited by 667
Metadata
- Authors
- DAHL, C. F., EWY, G. A., WARNER, E. D., & THOMAS, E. D.
- Venue
- Circulation
- Published
- 1974-11
- Volume
- 50
- Issue
- 5
- Pages
- 956-961
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2068303597
- Cited by
- 306
- References
- 3
- FWCI
- 1.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Myocardial Necrosis from Direct Current Countershock: Effect of Paddle Electrode Size and Time Interval Between Discharges. https://app.cochat.ai/papers/10.1161/01.cir.50.5.956
- The paper
- DAHL, C. F., EWY, G. A., WARNER, E. D., & THOMAS, E. D. (1974). Myocardial Necrosis from Direct Current Countershock: Effect of Paddle Electrode Size and Time Interval Between Discharges. Circulation. https://doi.org/10.1161/01.cir.50.5.956
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.