A comparative analysis of antegrade and retrograde conduction patterns in man.
Open accessThe DOI matches its Crossref record.
Abstract
Patterns of antegrade and retrograde conduction and refractory periods were studied using His bundle electrogram recordings, incremental atrial and ventricular pacing and the extrastimulus technique. In 36/50 patients antegrade conduction was "better" than retrograde conduction (group I), as evidenced by a) onset of retrograde atrioventricular (A-V) nodal Wenckebach phenomenon at a slower rate compared to the antegrade counterpart (25 patients: group IA) or b) no ventriculo-atrial conduction at all ventricular paced rates (11 pts: group IB). The site of retrograde block in group IB patients was the A-V node. In eight patients (group II), antegrade and retrograde conduction appeared to be equal up to maximum paced rates of 160 beats/min. In six patients (group III) retrograde conduction was "better" than antegrade conduction, as indicated by onset of antegrade A-V nodal Wenckebach periods at slower rates than retrograde Wenckebach periods. During antegrade refractory period studies the area of maximum refractoriness was the A-V node in 19/40 patients, the His-Purkinje system (HPS) 6/40, and the atrial muscle in 15/40. During retrograde refractory period studies the A-V node was the area of maximum refractoriness in 12/36 pts (4/40 patients had A-V dissociation during ventricular pacing), the HPS in 12/36, and the ventricular muscle in 10/36. In 2/36 patients the site of maximum refractoriness retrogradely could not be determined: The area of maximum refractoriness during both antegrade and retrograde refractory period studies was the same in 11 patients (A-V node in seve and HPS in four), was different (i.e., A-V node or HPS) in 18 patients, and was the artrial or ventricular muscle in six patients. In five patients, including four patients in whom V-A conduction failed to occur, the above comparisons were not made. It is concluded that 1) antegrade conduction is better than retrograde conduction in most patients; 2) it is not always possible to predict area of maximum refractoriness during premature stimulation (both atrium and ventricle) from observations made during incremental pacing; 3) it is equally difficult to extrapolate patterns of retrograde conduction and refractory periods from results of antegrade conduction and refractory period studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Short QT Syndrome: A Familial Cause of Sudden Death
Gaita, F., Giustetto, C., Bianchi, F., Wolpert, C., Schimpf, R., Riccardi, R., Grossi, S., Richiardi, E., & Borggrefe, M. (2003) · Circulation · doi:10.1161/01.cir.0000085071.28695.c4 · Cited by 708
Effects of digitalis on ventricular myocardial and His-Purkinje refractoriness and reentry in man
Gomes, J. A. C., Dhatt, M. S., Akhtar, M., Carambas, C. R., Rubenson, D. S., & Damato, A. N. (1978) · The American Journal of Cardiology · doi:10.1016/0002-9149(78)90678-1 · Cited by 22
Self-citation
Metadata
- Authors
- Akhtar, M., Damato, A. N., Batsford, W. P., Ruskin, J. N., & Ogunkelu, J. B.
- Venue
- Circulation
- Published
- 1975-11
- Volume
- 52
- Issue
- 5
- Pages
- 766-778
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1977857679
- Cited by
- 161
- References
- 0
- FWCI
- 7.30
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.