The DOI matches its Crossref record.
Cardiac imaging using a phased array ultrasound system. II. Clinical technique and application.
Abstract
A new two-dimensional ultrasound imaging system capable of producing high resolution tomographic images of the heart in real time has been developed. This system relies on phased array principles to rapidly steer the ultrasound beam through the structures under investigation. A hand-held linear array of 16 ultrasound transducers with overall dimensions of 14 mm at the site of contanct may be readily manipulated to image various cardiac structures. The resulting images are displayed in a circular sector format, 60 degrees in azimuth and typically 15 cm in range. At his maximum range, image frames consisting of 256 lines are generated at the rate of 20 frames/second. High azimuthal resolution throughout the field of view is assured by a focused transmit beam and by sweeping the focus of the receiver is synchrony with the range of returning echoes. Azimuthal resolution varies from 2 to 5 mm throughout the field of view while range resolution is 1.5 mm. This imaging system has proven particularly useful for the delineation of left ventricular spatial geometry by the identification of endocardium, myocardium, papillary muscles and interventricular septum. High quality images of anterior and posterior mitral leaflets, aortic root and aortic leaflets as well as left atrium and other cardiac structures have been obtained.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Maron, B. J., Gottdiener, J. S., & Epstein, S. E. (1981) · The American Journal of Cardiology · doi:10.1016/0002-9149(81)90068-0 · Cited by 607
Stewart, J. A., Silimperi, D., Harris, P., Wise, N. K., Fraker, T. D., & Kisslo, J. A. (1980) · Circulation · doi:10.1161/01.cir.61.2.374 · Cited by 261
Self-citationSchluter, M., Langenstein, B. A., Polster, J., Kremer, P., Souquet, J., Engel, S., & Hanrath, P. (1982) · Heart · doi:10.1136/hrt.48.1.67 · Cited by 168
Metadata
- Authors
- Kisslo, J., vonRamm, O. T., & Thurstone, F. L.
- Venue
- Circulation
- Published
- 1976-02
- Volume
- 53
- Issue
- 2
- Pages
- 262-267
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2060405994
- Cited by
- 163
- References
- 0
- FWCI
- 24.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cardiac imaging using a phased array ultrasound system. II. Clinical technique and application. https://app.cochat.ai/papers/10.1161/01.cir.53.2.262
- The paper
- Kisslo, J., vonRamm, O. T., & Thurstone, F. L. (1976). Cardiac imaging using a phased array ultrasound system. II. Clinical technique and application. Circulation. https://doi.org/10.1161/01.cir.53.2.262
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.