The DOI matches its Crossref record.
Quantitative coronary arteriography: estimation of dimensions, hemodynamic resistance, and atheroma mass of coronary artery lesions using the arteriogram and digital computation.
Abstract
More accurate characterization of coronary artery lesions is needed for evaluation of short and long-term interventions in coronary disease. A method of segmental artery analysis has been developed to maximize the information obtained from coronary arteriograms. Coronary lesions are traced from two projected, perpendicular, 35 mm cineangiographic views and transmetted, in digital form, to a PDP 11/45 computer. Magnification and distortion of the image are compensated for in order to determine the actual vessel profiles, using the catheter and its location as a scaling device. The two views are matched; a spatial representation of the vessel centerline is constructed mathematically; and orthogonal vessel diameters are computed at increments along this centerline. Assuming an elliptical lumen, the absolute and percentage reduction in diameter and cross-sectional area in the stenosis are computed. More complex functions (integrated atheroma mass, Poiseuille resistance, and orifice resistance) are then calculated. The accuracy and variability of the different steps involved in lesion analysis have been determined. Dimensional accuracies of +/- 150 microns (SD) are feasible. Examples are given of patients with Prinzmetal's angina and with progressive coronary disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Brown, G., Albers, J. J., Fisher, L. D., Schaefer, S. M., Lin, J.-T., Kaplan, C., Zhao, X.-Q., Bisson, B. D., Fitzpatrick, V. F., & Dodge, H. T. (1990) · New England Journal of Medicine · doi:10.1056/nejm199011083231901 · Cited by 2,159
Self-citationScanlon, P. J., Faxon, D. P., Audet, A.-M., Carabello, B., Dehmer, G. J., Eagle, K. A., Legako, R. D., Leon, D. F., Murray, J. A., Nissen, S. E., et al. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00126-6 · Cited by 1,123
Stary, H. C., Chandler, A. B., Dinsmore, R. E., Fuster, V., Glagov, S., Insull, W., Rosenfeld, M. E., Schwartz, C. J., Wagner, W. D., & Wissler, R. W. (1995) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.15.9.1512 · Cited by 965
A Randomized Trial Comparing Coronary Angioplasty with Coronary Bypass Surgery
King, S. B., Lembo, N. J., Weintraub, W. S., Kosinski, A. S., Barnhart, H. X., Kutner, M. H., Alazraki, N. P., Guyton, R. A., & Zhao, X.-Q. (1994) · New England Journal of Medicine · doi:10.1056/nejm199410203311602 · Cited by 734
Julius, B. K., Spillmann, M., Vassalli, G., Villari, B., Eberli, F. R., & Hess, O. M. (1997) · Circulation · doi:10.1161/01.cir.95.4.892 · Cited by 159
Metadata
- Authors
- Brown, B. G., Bolson, E., Frimer, M., & Dodge, H. T.
- Venue
- Circulation
- Published
- 1977-02
- Volume
- 55
- Issue
- 2
- Pages
- 329-337
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1965440677
- Cited by
- 633
- References
- 0
- FWCI
- 19.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitative coronary arteriography: estimation of dimensions, hemodynamic resistance, and atheroma mass of coronary artery lesions using the arteriogram and digital computation. https://app.cochat.ai/papers/10.1161/01.cir.55.2.329
- The paper
- Brown, B. G., Bolson, E., Frimer, M., & Dodge, H. T. (1977). Quantitative coronary arteriography: estimation of dimensions, hemodynamic resistance, and atheroma mass of coronary artery lesions using the arteriogram and digital computation. Circulation. https://doi.org/10.1161/01.cir.55.2.329
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.