Prognostic value of infranodal conduction time in patients with chronic bundle branch block.
Open accessThe DOI matches its Crossref record.
Abstract
His bundle recordings were obtained in 121 patients with chronic bundle branch block and the patients were followed for a mean period of 18 months. Seventy-nine patients had an infranodal conduction time (H-Q) less than 70 msec while 42 had H-Q greater than or equal to 70 msec. There was no significant difference in mean age, smoking history, diabetes, syncope, dizziness, blood pressure, and serum cholesterol or triglyceride levels between the two groups. There was a significantly greater incidence of progresssion to second degree or third degree atrioventricular block (9/42, 21%), and of severe congestive heart failure (16/42, 38%) in patients with H-Q greater than or equal to 70 compared with those with H-Q less than 70 (1/79, 1.3%; and 13/79, 16%, respectively). The risk of sudden death was significantly greater only in the group with H-Q greater than or equal to 70 and severe congestive heart failure. There was no correlation between the presence of first degree atrioventricular block and/or any particular type of bundle branch block pattern with sudden death and/or progression to second degree or third degree atrioventricular block. Analysis of the surface electrocardiogram is only of limited value in predicting high risk patients with chronic bundle branch block. Electrophysiologic studies are of greatest value in patients with bundle branch block with transient neurologic symptoms in whom no cause for the symptoms is evident.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
ACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.02.032 · Cited by 2,546
Writing Committee Members, Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., et al. (2008) · Circulation · doi:10.1161/circualtionaha.108.189742 · Cited by 1,774
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2013) · Circulation · doi:10.1161/cir.0b013e318276ce9b · Cited by 1,489
Gregoratos, G., Abrams, J., Epstein, A. E., Freedman, R. A., Hayes, D. L., Hlatky, M. A., Kerber, R. E., Naccarelli, G. V., Schoenfeld, M. H., Silka, M. J., et al. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02528-7 · Cited by 1,266
Committee Members, Gregoratos, G., Abrams, J., Epstein, A. E., Freedman, R. A., Hayes, D. L., Hlatky, M. A., Kerber, R. E., Naccarelli, G. V., Schoenfeld, M. H., et al. (2002) · Circulation · doi:10.1161/01.cir.0000035996.46455.09 · Cited by 910
Metadata
- Authors
- Scheinman, M. M., Peters, R. W., Modin, G., Brennan, M., Mies, C., & O'Young, J.
- Venue
- Circulation
- Published
- 1977-08
- Volume
- 56
- Issue
- 2
- Pages
- 240-244
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2133332219
- Cited by
- 138
- References
- 0
- FWCI
- 5.59
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Prognostic value of infranodal conduction time in patients with chronic bundle branch block. https://app.cochat.ai/papers/10.1161/01.cir.56.2.240
- The paper
- Scheinman, M. M., Peters, R. W., Modin, G., Brennan, M., Mies, C., & O'Young, J. (1977). Prognostic value of infranodal conduction time in patients with chronic bundle branch block. Circulation. https://doi.org/10.1161/01.cir.56.2.240
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.