Echocardiographic measurement of right ventricular wall thickness. A new application of subxiphoid echocardiography.
Open accessThe DOI matches its Crossref record.
Abstract
The feasibility of subxiphoid echocardiography to measure the thickness of the right ventricular wall (RVWT) was investigated. In 87 (90.6%) of the 96 patients studied, adequate visualization of the echoes from the right ventricular wall was obtained using the subxiphoid technique. RVWT averaged 0.34 +/- 0.08 cm (mean +/- 1 SD), ranging from 0.2 to 0.5 cm in 25 normal individuals. This was not significantly different from the values in the left ventricular overload group (0.36 +/- 0.10 cm). However, the RVWT was increased significantly (P less than 0.001) in the combined group (0.62 0.18 cm), the right ventricular (RV) pressure overload group (0.60 +/- 0.13 cm) and the RV volume overload group (0.53 +/- 0.11 cm). Thirty-two patients underwent diagnosis right heart catheterization which revealed a good correlation between the RVWT measured echocardiographically and the right ventricular peak systolic pressure (r = 0.84). Subxiphoid echocardiography was considered to be useful in diagnosing right ventricular hypertrophy in adults.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lang, R. M., Bierig, M., Devereux, R. B., Flachskampf, F. A., Foster, E., Pellikka, P. A., Picard, M. H., Roman, M. J., Seward, J., Shanewise, J. S., et al. (2005) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2005.10.005 · Cited by 11,318
Rudski, L. G., Lai, W. W., Afilalo, J., Hua, L., Handschumacher, M. D., Chandrasekaran, K., Solomon, S. D., Louie, E. K., & Schiller, N. B. (2010) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2010.05.010 · Cited by 7,049
Recommendations for chamber quantification☆
LANG, R., BIERIG, M., DEVEREUX, R., FLACHSKAMPF, F., FOSTER, E., PELLIKKA, P., PICARD, M., ROMAN, M., SEWARD, J., & SHANEWISE, J. (2006) · European Journal of Echocardiography · doi:10.1016/j.euje.2005.12.014 · Cited by 3,571
Echocardiographic Assessment of Valve Stenosis: EAE/ASE Recommendations for Clinical Practice
Baumgartner, H., Hung, J., Bermejo, J., Chambers, J. B., Evangelista, A., Griffin, B. P., Iung, B., Otto, C. M., Pellikka, P. A., & Quiñones, M. (2009) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2008.11.029 · Cited by 2,126
Abman, S. H., Hansmann, G., Archer, S. L., Ivy, D. D., Adatia, I., Chung, W. K., Hanna, B. D., Rosenzweig, E. B., Raj, J. U., Cornfield, D., et al. (2015) · Circulation · doi:10.1161/cir.0000000000000329 · Cited by 1,164
Metadata
- Authors
- Matsukubo, H., Matsuura, T., Endo, N., Asayama, J., & Watanabe, T.
- Venue
- Circulation
- Published
- 1977-08
- Volume
- 56
- Issue
- 2
- Pages
- 278-284
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2058424060
- Cited by
- 84
- References
- 0
- FWCI
- 1.20
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Echocardiographic measurement of right ventricular wall thickness. A new application of subxiphoid echocardiography. https://app.cochat.ai/papers/10.1161/01.cir.56.2.278
- The paper
- Matsukubo, H., Matsuura, T., Endo, N., Asayama, J., & Watanabe, T. (1977). Echocardiographic measurement of right ventricular wall thickness. A new application of subxiphoid echocardiography. Circulation. https://doi.org/10.1161/01.cir.56.2.278
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.