Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 194

The DOI matches its Crossref record.

Sudden death after repair of tetralogy of Fallot. Electrocardiographic and electrophysiologic abnormalities.

Gillette, P C, Yeoman, M A, Mullins, C E, McNamara, D G·1977·Circulation

Abstract

In order to try to determine the mechanism of sudded death in patients after surgical repair of tetralogy of Fallot, electrocardiographic, intracardiac electrophysiologic, and clinical data of 51 children who had postoperative intracardiac electrophysiologic studies were reviewed. Ninety-four percent had developed right bundle branch block (RBBB) and 16 percent had additional left anterior hemiblock (LAH). Two had had transient complete A-V block (CAVB) and one had permanent CAVB. Six had a first degree A-V block and nine had premature ventricular contractions (PVC). Nine patients were found to have prolonged intra-atrial conduction times, four prolonged A-V nodal conduction, four prolonged His-Purkinje conduction, and five prolonged corrected sinus node recovery times. Patients with first degree A-V block or LAH did not have an increased incidence of abnormalities on electrophysiologic study. No patient with RBBB and LAH developed complete A-V block or died. Three of the nine patients with PVCs died, one of intractable ventricular fibrillation and two suddenly, presumably of dysrhythmia. All three had significant congestive heart failure. Although late complete A-V block occurs and should be watched for, ventricular dysrhythmias in patients with PVCs may be the cause of most sudden deaths after tetralogy repair. We currently are treating all of our postoperative tetralogy patients who have PVCs with quinidine or propranolol.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.56.4.566

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 194

Metadata

Authors
Gillette, P. C., Yeoman, M. A., Mullins, C. E., & McNamara, D. G.
Venue
Circulation
Published
1977-10
Volume
56
Issue
4
Pages
566-571
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2053766461
Cited by
194
References
0
FWCI
5.85
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Sudden death after repair of tetralogy of Fallot. Electrocardiographic and electrophysiologic abnormalities. https://app.cochat.ai/papers/10.1161/01.cir.56.4.566
The paper
Gillette, P. C., Yeoman, M. A., Mullins, C. E., & McNamara, D. G. (1977). Sudden death after repair of tetralogy of Fallot. Electrocardiographic and electrophysiologic abnormalities. Circulation. https://doi.org/10.1161/01.cir.56.4.566

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.