Dissecting aortic aneurysm associated with congenital bicuspid aortic valve.
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Among 119 cases of fatal dissecting aneurysm of the aorta, exclusive of those iatrogenically caused or associated with arachnodactyly or aortic stenosis, there were observed 11 cases of congenital bicuspid aortic valve (9%). The ages ranged from 17 to 69 years, five of the patients being 29 years old or younger. Among the latter, three had coarctation of the aorta and one had Turner's syndrome without coarctation. In one of the older patients, aortic insufficiency was present. Hypertension was either established or inferred from cardiac weight in 73% of the cases. In each case, cystic medial necrosis of the aorta was present. Prolapse of valves other than the aortic was observed in 45% of the cases with bicuspid aortic valve. Compared to an estimated incidence of bicuspid aortic valve of about 1 to 2% in the population, the high incidence among subjects with dissecting aneurysm suggests a causative relationship between bicuspid aortic valve and aortic dissecting aneurysm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The congenitally bicuspid aortic valve
Roberts, W. C. (1970) · The American Journal of Cardiology · doi:10.1016/0002-9149(70)90761-7 · Cited by 924
Cystic medial necrosis of the ascending aorta in relation to age and hypertension
Carlson, R. G., Lillehei, C. W., & Edwards, J. E. (1970) · The American Journal of Cardiology · doi:10.1016/0002-9149(70)90006-8 · Cited by 184
Self-citationASSOCIATION OF CONGENITAL BICUSPID AORTIC VALVE AND ERDHEIM'S CYSTIC MEDIAL NECROSIS
Mckusick, V. (1972) · The Lancet · doi:10.1016/s0140-6736(72)91211-1 · Cited by 184
Cited by
A classification system for the bicuspid aortic valve from 304 surgical specimens
Sievers, H.-H., & Schmidtke, C. (2007) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2007.01.039 · Cited by 1,222
Risk factors for aortic dissection: A necropsy study of 161 cases
Larson, E. W., & Edwards, W. D. (1984) · The American Journal of Cardiology · doi:10.1016/0002-9149(84)90418-1 · Cited by 910
Self-citationSvensson, L. G., Kouchoukos, N. T., Miller, D. C., Bavaria, J. E., Coselli, J. S., Curi, M. A., Eggebrecht, H., Elefteriades, J. A., Erbel, R., Gleason, T. G., et al. (2008) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2007.10.099 · Cited by 860
Incidence of Aortic Complications in Patients With Bicuspid Aortic Valves
Michelena, H. I., Khanna, A. D., Mahoney, D., Margaryan, E., Topilsky, Y., Suri, R. M., Eidem, B., Edwards, W. D., Sundt, T. M., & Enriquez-Sarano, M. (2011) · JAMA · doi:10.1001/jama.2011.1286 · Cited by 825
Self-citationClinical significance of the bicuspid aortic valve
Ward, C. (2000) · Heart · doi:10.1136/heart.83.1.81 · Cited by 803
Metadata
- Authors
- Edwards, W. D., Leaf, D. S., & Edwards, J. E.
- Venue
- Circulation
- Published
- 1978-05
- Volume
- 57
- Issue
- 5
- Pages
- 1022-1025
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2040749098
- Cited by
- 266
- References
- 3
- FWCI
- 4.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.