The DOI matches its Crossref record.
Severe aortic stenosis with impaired left ventricular function and clinical heart failure: results of valve replacement.
Open accessAbstract
Nineteen patients, aged 58-80 years, with severe isolated aortic valve stenosis, severely reduced ejection fraction and clinical heart failure underwent aortic valve replacement between January 1970 and April 1977. Ten had concomitant coronary artery disease (all underwent additional coronary bypass surgery), 17 had angina pectoris and four had syncope. Aortic valve area index was 0.32 +/- 0.03 cm2/m2 (mean +/- SEM); left ventricular (LV) end-diastolic volume index was 117 +/- 9 ml/m2 and LV ejection fraction was 0.37 +/- 0.02. There were four operative deaths and one late death. The follow-up time ranged from six to 74 months (38 +/- 6 months). Actuarially determined three-year survival is 74 +/- 10%; the expected five-year survival is the same. One patient had a serious cerebrovascular accident. Of the remaining survivors, seven were initially Functional Class IV and six Class III; currently, six are Class I and seven Class II (New York Heart Association classifications). The cardiothoracic ratio has decreased from 0.54 +/- 0.03 to 0.49 +/- 0.03. Repeat hemodynamic evaluation has been performed in 10 patients, 22 +/- 6 months after surgery. In these 10 patients, the aortic valve gradient decreased from 55 +/- 7 11 +/- 1.3 mm Hg; LV end-diastolic pressure from 22 +/- 2.4 to 9 +/- 1.9 mm Hg; LV end-diastolic volume index from 119 +/- 16 ml/m2 to 107 +/- 11 ml/m2. LV ejection fraction has increased dramatically from 0.34 +/- 0.03 to 0.63 +/- 0.05 and mean velocity of circumferential fiber shortening from 0.57 +/- 0.08 to 1.3 +/- 0.18 circ/sec. The encouraging long-term survival, improved functional class and the marked improvement in left ventricular function that occurred in our patients indicate that all patients with severe aortic stenosis in clinical heart failure should be offered aortic valve replacement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sex-associated differences in left ventricular function in aortic stenosis of the elderly.
Carroll, J. D., Carroll, E. P., Feldman, T., Ward, D. M., Lang, R. M., McGaughey, D., & Karp, R. B. (1992) · Circulation · doi:10.1161/01.cir.86.4.1099 · Cited by 488
Aortic Valve Replacement for Low-Flow/Low-Gradient Aortic Stenosis
Levy, F., Laurent, M., Monin, J. L., Maillet, J. M., Pasquet, A., Le Tourneau, T., Petit-Eisenmann, H., Gori, M., Jobic, Y., Bauer, F., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.10.067 · Cited by 279
Metadata
- Authors
- Smith, N., McAnulty, J. H., & Rahimtoola, S. H.
- Venue
- Circulation
- Published
- 1978-08
- Volume
- 58
- Issue
- 2
- Pages
- 255-264
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2027986884
- Cited by
- 266
- References
- 0
- FWCI
- 9.11
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Severe aortic stenosis with impaired left ventricular function and clinical heart failure: results of valve replacement. https://app.cochat.ai/papers/10.1161/01.cir.58.2.255
- The paper
- Smith, N., McAnulty, J. H., & Rahimtoola, S. H. (1978). Severe aortic stenosis with impaired left ventricular function and clinical heart failure: results of valve replacement. Circulation. https://doi.org/10.1161/01.cir.58.2.255
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.