The DOI matches its Crossref record.
A new method for measurement of sinoatrial conduction time.
Open accessAbstract
This study describes a new method (NM) for estimation of sinoatrial conduction time (SACT), which utilizes constant atrial pacing (AP) instead of the premature atrial beats (PABs) used in the method reported in 1973 by Strauss et al. The SACTs were obtained by both methods in 20 patients. The SACT by the Strauss method (SM) was calculated as A2A3 minus A1A1. The NM consists of high right AP for a train of eight consecutive beats at rates less than or equal to 10 beats/min faster than the sinus rhythm. The interval between the last paced atrial electrogram (Ap) and the first escape atrial electrogram (A) of sinus origin (Ap-A) was measured along with several post pacing sinus cycles. The SACT by the NM was calculated as follows: SACT = Ap-A minus A1A1. The effect of AP at higher rates was also analyzed. In two patients, the SACT with the SM could not be defined, as all the A2A3 intervals were fully compensatory; with the NM the SACT was 217 and 320 msec. In the remaining 18 patients the SACT was obtainable by both methods. With SM, the SACT ranged 105--452 msec (mean 219 +/- 102 SD) and with the NM it was 85--492 msec (mean 201 +/- 112 SD), and the difference was statistically significant (P = 0.0162). The coefficient of correlation between the two methods was r = 0.97. During AP at faster rates, a rate related increment in Ap-A intervals and also post pacing sinus cycles was noted. This study describes a new and simple method for measurement of SACT in man.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.10.044 · Cited by 1,008
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000628 · Cited by 603
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.10.043 · Cited by 337
Guidelines for clinical intracardiac electrophysiological and catheter ablation procedures
Zipes, D. P., Dimarco, J. P., Gillette, P. C., Jackman, W. M., Myerburg, R. J., Rahimtoola, S. H., Ritchie, J. L., Cheitlin, M. D., Garson, A., Gibbons, R. J., et al. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)80037-h · Cited by 282
A novel pacing maneuver to localize focal atrial tachycardia
MOHAMED, U., SKANES, A. C., GULA, L. J., LEONG‐SIT, P., KRAHN, A. D., YEE, R., SUBBIAH, R., & KLEIN, G. J. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2006.00664.x · Cited by 164
Metadata
- Authors
- Narula, O. S., Shantha, N., Vasquez, M., Towne, W. D., & Linhart, J. W.
- Venue
- Circulation
- Published
- 1978-10
- Volume
- 58
- Issue
- 4
- Pages
- 706-714
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2050452285
- Cited by
- 238
- References
- 0
- FWCI
- 3.42
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A new method for measurement of sinoatrial conduction time. https://app.cochat.ai/papers/10.1161/01.cir.58.4.706
- The paper
- Narula, O. S., Shantha, N., Vasquez, M., Towne, W. D., & Linhart, J. W. (1978). A new method for measurement of sinoatrial conduction time. Circulation. https://doi.org/10.1161/01.cir.58.4.706
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.