The Measurement of the Q-T Interval of the Electrocardiogram

LEPESCHKIN, EUGENE, SURAWICZ, BORYS·1952·Circulation

Abstract

The sources of error in determination of the beginning of QRS and the end of T during measurement of the Q-T duration are analyzed. An important error is confusion of an elevated U wave with the T wave, resulting in the diagnosis of a prolonged Q-T. In such cases, some of the precordial leads usually show a notch or kink between T and U which indicates approximately the end of T. If these criteria are used, the true corrected Q-T duration in hypopotassemia without hypocalcemia is not prolonged, but normal or shortened, corresponding to an earlier appearance of the second heart sound.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.6.3.378

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 624

Metadata

Authors
LEPESCHKIN, E., & SURAWICZ, B.
Venue
Circulation
Published
1952-09
Volume
6
Issue
3
Pages
378-388
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1994873020
Cited by
624
References
0
FWCI
5.58
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Measurement of the Q-T Interval of the Electrocardiogram. https://app.cochat.ai/papers/10.1161/01.cir.6.3.378
The paper
LEPESCHKIN, E., & SURAWICZ, B. (1952). The Measurement of the Q-T Interval of the Electrocardiogram. Circulation. https://doi.org/10.1161/01.cir.6.3.378

Data sources