Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 286

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Determination of right atrial and right ventricular size by two-dimensional echocardiography.

Bommer, W, Weinert, L, Neumann, A, Neef, J, Mason, D T, DeMaria, A·1979·Circulation

Abstract

No data are available on determining right atrial and right ventricular size by two-dimensional echocardiography. We performed two-dimensional echocardiograms on eight human right-heart casts obtained at autopsy and on 50 patients who underwent complete left- and right-heart catheterization. Measurement of individual dimensions of the long and short axes of the right atrium and ventricle from right heart casts closely correlated with the volume of these structures as determined by water displacement. Further, individual dimensions by cross-sectional echo correlated well with actual casts dimensions. Subsequently, echocardiographic measurements of right atrial and ventricular long and short axes were obtained in the apical four-chambered view in a group of normals and compared with a group of patients with right ventricular volume overload states. Mean values for right atrial short-axis and long-axis measurements were greater in right ventricular volume overload patients than in normals: 6.5 +/- 0.3 vs 3.6 +/- 0.1 cm, and 6.0 +/- 0.3 vs 4.2 +/- 0.1 cm, respectively (both p less than 0.001). In addition, measurements of both individual dimensions as well as planed area of the right ventricle were greater in right ventricular volume overload patients than in normals: maximal short axis 6.1 +/- 0.3 vs 3.5 +/- 0.2 cm, mid-short axis 6.1 %/- 0.4 vs 2.8 +/- 0.2 cm, and area 40 +/- 2.6 vs 18 +/- 1.2 cm2 (all p less than 0.001). There were no differences in right ventricular long-axis measurement. Two-dimensional echocardiography provided better separation of normals from right ventricular volume overload patients than did M-mode techniques. Thus, two-dimensional echocardiography, with the apical four-chambered view, enables accurate visualization of the right atrium and ventricle in almost all patients. Futher, measurements of right atrial and right ventricular size by two-dimensional echocardiography readily distinguish normal patients from those with right ventricular volume overload.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.60.1.91

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 286

Metadata

Authors
Bommer, W., Weinert, L., Neumann, A., Neef, J., Mason, D. T., & DeMaria, A.
Venue
Circulation
Published
1979-07
Volume
60
Issue
1
Pages
91-100
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2058298946
Cited by
286
References
2
FWCI
9.21
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Determination of right atrial and right ventricular size by two-dimensional echocardiography. https://app.cochat.ai/papers/10.1161/01.cir.60.1.91
The paper
Bommer, W., Weinert, L., Neumann, A., Neef, J., Mason, D. T., & DeMaria, A. (1979). Determination of right atrial and right ventricular size by two-dimensional echocardiography. Circulation. https://doi.org/10.1161/01.cir.60.1.91

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.