The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Aortic input impedance in normal man: relationship to pressure wave forms.
Abstract
SUMMARY The relationship between the shape of the ascending aortic pressure wave form and aortic input impedance was studied in 18 patients who underwent elective cardiac catheterization but in whom no heart dis-ease was found. Ascending aortic flow velocity and pressure were simultaneously recorded from a multisensor catheter with an electromagnetic velocity probe and a pressure sensor mounted at the same location. Another pressure sensor at the catheter tip provided left ventricular pressure or a second aortic pressure to determine pulse-wave velocity. Fick cardiac outputs were used to scale the velocity signal to instantaneous volumetric flow. Input impedance was calculated from 10 harmonics of aortic pressure and flow. For each patient, im-pedance moduli and phases from a minimum of 15 beats during a steady state were averaged. Peripheral resistance was 1137 ± 39 dyn-sec-cm ' (4 SEM) and characteristic impedance was 47 4 4 dyn-sec-cm-; pulse-wave velocity was 6.68 ± 0.32 m-sec-'. In all patients, a well-defined systolic inflection point divided the aortic pressure wave form into an early and late systolic phase. The patients were classified into three groups: group A (n = 7) patients whose late systolic pressure exceeded early systolic pressure; group B (n = 7) pa-tients whose early and late systolic pressures were nearly equal; group C (n = 4)- patients whose early systolic pressure exceeded late systolic pressure. Group A and B patients all demonstrated oscillations of the impedance moduli about the characteristic impedance. Group C patients demonstrated flatter impedance spec-
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A METHOD FOR JUDGING ALL CONTRASTS IN THE ANALYSIS OF VARIANCE*
SCHEFFÉ, H. (1953) · Biometrika · doi:10.1093/biomet/40.1-2.87 · Cited by 1,705
McDonald, D. A. (1963) · The American Journal of the Medical Sciences · doi:10.1097/00000441-196301000-00017 · Cited by 1,565
Ross, J. (1976) · Progress in Cardiovascular Diseases · doi:10.1016/0033-0620(76)90021-9 · Cited by 654
Pressure-flow relationships and vascular impedance in man
Mills, C. J., Gabe, I. T., Gault, J. H., Mason, D. T., Ross, J., Braunwald, E., & Shillingford, J. P. (1970) · Cardiovascular Research · doi:10.1093/cvr/4.4.405 · Cited by 363
The role of vasodilator therapy in heart failure
Chatterjee, K., & Parmley, W. W. (1977) · Progress in Cardiovascular Diseases · doi:10.1016/0033-0620(77)90006-8 · Cited by 315
Pressure-flow relationships in the ascending aorta and femoral artery of man
Patel, D. J., Greenfield, J. C., Austen, W. G., Morrow, A. G., & Fry, D. L. (1965) · Journal of Applied Physiology · doi:10.1152/jappl.1965.20.3.459 · Cited by 114
Westerhof, N., Elzinga, G., & van den Bos, G. C. (1973) · Medical & Biological Engineering & Computing · doi:10.1007/bf02478659 · Cited by 107
Self-citationReflection in the systemic arterial system: effects of aortic and carotid occlusion
van den Bos, G. C., Westerhof, N., Elzinga, G., et al. (1976) · Cardiovascular Research · doi:10.1093/cvr/10.5.565 · Cited by 75
Self-citationThe Measurement of Input Impedance and Apparent Phase Velocity in the Human Aorta
GABE, I. T., Karnell, J., Porjé, I. G., & Rudewald, B. (1964) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1964.tb02944.x · Cited by 59
Effective length of the arterial system
Sipkema, P., & Westerhof, N. (1975) · Annals of Biomedical Engineering · doi:10.1007/bf02390974 · Cited by 44
Self-citationIMPEDANCE OF CERTAIN LARGE BLOOD VESSELS IN MAN
Patel, D. J., Austen, W. G., Greenfield, J. C., & Tindall, G. T. (1964) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1964.tb50685.x · Cited by 31
Cited by
Arterial Stiffness and Cardiovascular Events: The Framingham Heart Study
Mitchell, G. F., Hwang, S.-J., Vasan, R. S., Larson, M. G., Pencina, M. J., Hamburg, N. M., Vita, J. A., Levy, D., & Benjamin, E. J. (2010) · Circulation · doi:10.1161/circulationaha.109.886655 · Cited by 2,225
Aboyans, V., Criqui, M. H., Abraham, P., Allison, M. A., Creager, M. A., Diehm, C., Fowkes, F. G. R., Hiatt, W. R., Jönsson, B., Lacroix, P., et al. (2012) · Circulation · doi:10.1161/cir.0b013e318276fbcb · Cited by 1,703
Mitchell, G. F., Parise, H., Benjamin, E. J., Larson, M. G., Keyes, M. J., Vita, J. A., Vasan, R. S., & Levy, D. (2004) · Hypertension · doi:10.1161/01.hyp.0000128420.01881.aa · Cited by 1,501
Townsend, R. R., Wilkinson, I. B., Schiffrin, E. L., Avolio, A. P., Chirinos, J. A., Cockcroft, J. R., Heffernan, K. S., Lakatta, E. G., McEniery, C. M., Mitchell, G. F., et al. (2015) · Hypertension · doi:10.1161/hyp.0000000000000033 · Cited by 1,473
Normal Vascular Aging: Differential Effects on Wave Reflection and Aortic Pulse Wave Velocity
McEniery, C. M., Yasmin, Hall, I. R., Qasem, A., Wilkinson, I. B., & Cockcroft, J. R. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.07.037 · Cited by 1,359
Metadata
- Authors
- Murgo, J. P., Westerhof, N., Giolma, J. P., & Altobelli, S. A.
- Venue
- Circulation
- Published
- 1980-07
- Volume
- 62
- Issue
- 1
- Pages
- 105-116
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1985023991
- Cited by
- 1,014
- References
- 11
- FWCI
- 4.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.