The DOI matches its Crossref record.
Combined doppler and phased-array echocardiographic estimation of cardiac output.
Open accessAbstract
The capability of a pulsed Doppler flowmeter combined with a phased-array imaging system to measure volume flow was tested in vitro and in patients undergoing cardiac catheterization. The Doppler-phased-array system (DPA) was used to determine vessel diameter and a superimposed cursor was used to locate the range and angle of the Doppler sample volume. DPA estimates of continuous flow through tubing in a water tank correlated strongly (r = 0.99) with measured flow corresponding to physiologic ranges from 3-12 l/min. For pulsatile flow in a water tank, a correlation of r = 0.86 with measured flow was obtained, whereas DPA estimates of cardiac outputs compared with Fick estimates in the 11 patients produced a correlation of r = 0.83. These data indicate that estimates of cardiac output are possible using the DPA approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Determination of cardiac output by Doppler echocardiography.
Ihlen, H., Amlie, J. P., Dale, J., Forfang, K., Nitter-Hauge, S., Otterstad, J. E., Simonsen, S., & Myhre, E. (1984) · Heart · doi:10.1136/hrt.51.1.54 · Cited by 337
Measurement of arterial blood flow by Doppler ultrasound
Hoskins, P. R. (1990) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/11/1/001 · Cited by 109
Metadata
- Authors
- Magnin, P. A., Stewart, J. A., Myers, S., von Ramm, O., & Kisslo, J. A.
- Venue
- Circulation
- Published
- 1981-02
- Volume
- 63
- Issue
- 2
- Pages
- 388-392
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2036404057
- Cited by
- 161
- References
- 0
- FWCI
- 9.99
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Combined doppler and phased-array echocardiographic estimation of cardiac output. https://app.cochat.ai/papers/10.1161/01.cir.63.2.388
- The paper
- Magnin, P. A., Stewart, J. A., Myers, S., von Ramm, O., & Kisslo, J. A. (1981). Combined doppler and phased-array echocardiographic estimation of cardiac output. Circulation. https://doi.org/10.1161/01.cir.63.2.388
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.