The DOI matches its Crossref record.
Use of signals in the terminal QRS complex to identify patients with ventricular tachycardia after myocardial infarction.
Open accessAbstract
Small, high-frequency electrocardiographic signals were recorded from the body surface in 39 patients with and 27 patients without ventricular tachycardia (VT). All patients were in normal sinus rhythm, had a previous myocardial infarction, were not taking antiarrhythmic drugs, and did not have bundle branch block. Bipolar X, Y, Z leads were signal averaged and processed by a bidirectional digital filter that allowed low-amplitude signals to be detected in the terminal QRS complex and ST segment. The high-pass filter frequency was 25 Hz. Patients with VT had a lower amplitude of high-frequency signal in the late QRS complex. In the last 40 msec of the filtered QRS complex, the patients with VT had 14.9 +/- 14.4 microV of high-frequency signal; patients without VT had 73.8 +/- 47.7 microV (p less than 0.0001). Ninety-two percent of the patients with VT had less than 25 microV of high-frequency voltage; only 7% of patients without VT had less than 25 microV (p less than 0.0001). Patients with VT had a longer QRS duration than those without VT, 139 +/- 26 vs 95 +/- 10 msec (p less than 0.0001). The QRS duration was longer than 120 msec in 72% of the patients with VT but in none of the patients without VT (p less than 0.0001). In all patients there was no separate and discrete high-frequency signal in the ST segment. Advanced signal processing of the ECG accurately identified the patients in the study with VT after myocardial infarction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Schmidt, G., Malik, M., Barthel, P., Schneider, R., Ulm, K., Rolnitzky, L., Camm, A. J., Bigger, J. T., & Schömig, A. (1999) · The Lancet · doi:10.1016/s0140-6736(98)08428-1 · Cited by 716
Anthony Gomes, J., Winters, S. L., Stewart, D., Horowitz, S., Milner, M., & Barreca, P. (1987) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(87)80018-9 · Cited by 438
Cripps, T. R., Malik, M., Farrell, T. G., & Camm, A. J. (1991) · Heart · doi:10.1136/hrt.65.1.14 · Cited by 301
QT Dynamicity and Sudden Death After Myocardial Infarction: Results of a Long‐Term Follow‐Up Study
CHEVALIER, P., BURRI, H., ADELEINE, P., KIRKORIAN, G., LOPEZ, M., LEIZOROVICZ, A., ANDRÉ‐FOUËT, X., CHAPON, P., RUBEL, P., & TOUBOUL, P. (2003) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2003.02431.x · Cited by 94
Non-invasive imaging of arrhythmogenic left-ventricular myocardium after infarction
Leder, U., Haueisen, J., Huck, M., & Nowak, H. (1998) · The Lancet · doi:10.1016/s0140-6736(98)00082-8 · Cited by 48
Metadata
- Authors
- Simson, M. B.
- Venue
- Circulation
- Published
- 1981-08
- Volume
- 64
- Issue
- 2
- Pages
- 235-242
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2161963243
- Cited by
- 1,107
- References
- 0
- FWCI
- 8.96
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Use of signals in the terminal QRS complex to identify patients with ventricular tachycardia after myocardial infarction. https://app.cochat.ai/papers/10.1161/01.cir.64.2.235
- The paper
- Simson, M. B. (1981). Use of signals in the terminal QRS complex to identify patients with ventricular tachycardia after myocardial infarction. Circulation. https://doi.org/10.1161/01.cir.64.2.235
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.