The DOI matches its Crossref record.
Sustained ventricular tachycardia: role of the 12-lead electrocardiogram in localizing site of origin.
Abstract
SUMMARY The QRS morphology of the 12-lead ECG of 41 morphologically distinct ventricular tachycar-dias (VT) was correlated with their site of origin as determined by catheter and intraoperative mapping. Twenty-two VT patterns had a right bundle branch block (VT-RBBB) morphology and 19 a left bundle branch block (VT-LBBB) morphology. All VT-RBBBs arose in the left ventricle. All 16 VT-LBBBs in patients with coronary artery disease (CAD) arose from the LV at sites on or adjacent to the septum. Three VT-LBBBs in patients without CAD arose in the right ventricle. The 12-lead ECG could not precisely identify the site of origin in patients with CAD but could differentiate anterior from posterobasal regions, particularly in VT-LBBB. The ECG was less useful in localizing VT-RBBB because of overlapping patterns. General patterns that were useful in differentiating anterior from posterobasal sites of origin included: (1) The presence of a q wave in leads 1 and V,, was seen in VT-RBBB or VT-LBBB originating anteriorly but not in VT of postero-basal or posterior septal origin. (2) R waves in leads 1 and V, to V, in VT-RBBB, and in leads 1, V2, V3 and V6 in VT-LBBB were specific for a posterior origin, and not observed in VT of anterior origin. (3) In VT-LBBB with a superior axis, a q wave in leads 1 and V6 was specific for origin along the inferior aspect of the anterior septum. (4) All VT-LBBB with an inferior and rightward axis originated from the superior aspect of the anterior septum. We conclude that although selected ECG features are useful in locating the origins of VT,
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias
Cronin, E. M., Bogun, F. M., Maury, P., Peichl, P., Chen, M., Namboodiri, N., Aguinaga, L., Leite, L. R., Al-Khatib, S. M., Anter, E., et al. (2019) · EP Europace · doi:10.1093/europace/euz132 · Cited by 475
Self-citation2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias
Cronin, E. M., Bogun, F. M., Maury, P., Peichl, P., Chen, M., Namboodiri, N., Aguinaga, L., Leite, L. R., Al-Khatib, S. M., Anter, E., et al. (2020) · Heart Rhythm · doi:10.1016/j.hrthm.2019.03.002 · Cited by 431
Self-citationDIXIT, S., GERSTENFELD, E. P., CALLANS, D. J., & MARCHLINSKI, F. E. (2003) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2003.02404.x · Cited by 283
Self-citationKindwall, K. E., Brown, J., & Josephson, M. E. (1988) · The American Journal of Cardiology · doi:10.1016/0002-9149(88)91169-1 · Cited by 253
Self-citation
Metadata
- Authors
- Josephson, M. E., Horowitz, L. N., Waxman, H. L., Cain, M. E., Spielman, S. R., Greenspan, A. M., Marchlinski, F. E., & Ezri, M. D.
- Venue
- Circulation
- Published
- 1981-08
- Volume
- 64
- Issue
- 2
- Pages
- 257-272
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2039698776
- Cited by
- 163
- References
- 0
- FWCI
- 7.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sustained ventricular tachycardia: role of the 12-lead electrocardiogram in localizing site of origin. https://app.cochat.ai/papers/10.1161/01.cir.64.2.257
- The paper
- Josephson, M. E., Horowitz, L. N., Waxman, H. L., Cain, M. E., Spielman, S. R., Greenspan, A. M., Marchlinski, F. E., & Ezri, M. D. (1981). Sustained ventricular tachycardia: role of the 12-lead electrocardiogram in localizing site of origin. Circulation. https://doi.org/10.1161/01.cir.64.2.257
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.